background image

6

Getting

Started

...

Getting

 started...

GB

IE

Before 

you

 start

 

07

Safety

  

09

 

Summary of Contents for GCLED100BK

Page 1: ...60901110_04 GCLED60_70_90_100 SS BK W GB IE GCLED60 70 90 100 SS BK W Curved Glass LED Hood ...

Page 2: ... 01 x 1 04 x 2 05 x 1 02 x 1 03 x 1 06 x 1 07 x 4 ...

Page 3: ...1 1 11 x 4 12 x 6 3 9 x 32mm 08 x 4 10 x 6 09 x 1 13 x 4 3 4 x 10mm ...

Page 4: ...GB IE Curved Glass Cooker Hood 05 Installation 23 GCLED60 70 90 100 SS BK W 4 ...

Page 5: ... 07 Safety 09 In more detail 13 Product functions Operation Care and maintenance Troubleshooting Recycling and disposal Technical and legal information CE Declaration of conformity 14 14 15 18 19 19 22 Appendix GB IE Installation Information for EU66 23 32 ...

Page 6: ...6 Getting Started Getting started GB IE Before you start 07 Safety 09 ...

Page 7: ...hat it is not damaged If in doubt do not use the appliance K U 8 2 1 1 0 0 8 4 4 3 0 n o s e c i v r e S r e m o t s u C t c a t n o c t u b 01 4475261 Ireland Check the package and make sure you have all of the parts listed Decide on the appropriate location for your product or handling to prevent personal injury or damage to the product ordering replacement parts If you sell the appliance give i...

Page 8: ...quired Ø6mm CARBFILT4 UK IE SELF ADHESIVE ALUMINIUM TAPE Accessories not supplied Recirculation Extraction CARBON FILTER ORDERING HOTLINE 0344 800 1128 UK 01 4475261 IE Ø125mm or Ø150mm VENT PACK 2 UK IE 8 Getting started GB IE ...

Page 9: ...g hot during its operation Accessible parts may become hot during use Young children should be kept away Care should be taken to avoid touching the appliance The Manufacturer highly recommends that this appliance be kept out of the reach of babies and small children This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities o...

Page 10: ...ged it must be replaced by the manufacturer its order to avoid a hazard Do not allow the electric cables to touch the hot parts of the appliance Make sure that the power cord is not caught under or in the appliance and avoid damage to the power cable Do not install the appliance outdoors in a damp place or in an area which may be prone to water leaks such as under or near a sink unit In the event ...

Page 11: ...es outlets Do not connect the hood to that room ventilation is appropriate with the local authorities Make sure the maximum air room does not exceed 4 Pa 0 04 mbar The room must have adequate ventilation if an extractor hood is used simultaneously with appliances that run on gas or other fuels The used for exhausting fumes fromappliances burning gas or other fuels Regulations regarding air extract...

Page 12: ...gns of damage or imperfection Contact customer services Flambe cooking must not be carried out underneath this appliance When installing the appliance make sure that the following distances between the top of cooker or hob and the lowest part of the cooker hood must be observed Gas hobs 750mm Electric hobs 650mm The Manufacturer declines all liability for personal or material damage as a result of...

Page 13: ...In more detail In more detail GB IE Product functions 14 Operation 14 Care and maintenance 15 Troubleshooting 18 Recycling and disposal 19 Technical and legal information 19 CE Declaration of conformity 22 ...

Page 14: ...ppliance at the switched fused connection unit The appliance is ready for operation functions Five button panel Lighting on and off Extractor fan off Extractor fan speed button speed 1 Extractor fan speed button speed 2 Extractor fan speed button speed 3 To obtain the best results from your cooker hood it is recommended that you leave it switched on for 15 minutes after Product Functions Operation...

Page 15: ...always switch off the electricity supply before carrying out maintenance work on the hood In the event of a fault contact customer services Bulb replacement The Bulb may be hot leave it 10 minutes before removing it 10 FUSE OFF 15 In more detail GB IE ...

Page 16: ...Care and maintenance 2 X ACTIVE CHARCOAL FILTER NOT SUPPLIED MODEL NUMBER CARBFILT4 UK IE CLICK 16 In more detail GB IE ...

Page 17: ...e the cleaning process Important the hood is used for more than 2 hours a day Always use genuine Care and maintenance FUSE OFF Warning Always switch off the electricity supply before performing maintenance work In the event of a fault contact customer services 3 MONTH 1 MONTH MAX 65 C 17 In more detail GB IE ...

Page 18: ... supply Suction performance reduced Speed may be too low Select a higher speed Distance between the cooker hood and the hob is too great Readjust the distance to Gas hobs 750mm Electric hobs 650mm dirty and maintenance Top vent might be obstructed VHB60SS VH60W Clear any obstruction Optional vent kit might be twisted Ensure that the vent kit is instructions Works normally but cooking smells linger...

Page 19: ...is product is disposed of correctly you will help to avoid possible negative consequences for the environment and public health which could occur if this product is not handled correctly To receive more detailed information about recycling this product contact your local government domestic waste disposal services or the outlet where the product was bought Technical and legal information The Manuf...

Page 20: ... A 3AMP FUSE FUSE ON EUR UK Direct Connection If the appliance is being connected directly to the mains an omnipolar circuit breaker must be installed with a minimum opening of 3mm between contacts If the supply cord is damaged it must be replaced by the order to avoid a hazard The installer must ensure that the correct electrical connection has been made and that it complies with wiring diagram T...

Page 21: ...NCE MUST NOT BE EARTHED The appliance is supplied with a 2 core mains cable and must be connected to the electricity supply via a double pole switch having a 3mm minimum contact gap on each connector For UK only A Switched Fused Connection Unit to BS 1363 Part 4 is recommended The fuse must be rated at 3 Amps The wires in the mains lead are coloured in accordance with the following code Brown L Li...

Page 22: ...lectrical appliances Standard EN 60335 part 2 31 particular requirements for range hoods Standard EN 55014 Limits and methods of measurement of radio disturbance Standard EN 61000 3 2 Electromagnetic compatibility limits for harmonic Standard EN 61000 4 5 Electromagnetic compatibility EMC APPLIED INTERNATIONAL TECHNICAL STANDARDS AND SPECIFICATIONS ISO9001 2008 PLACE Torelló APPLIED HARMONIZED STA...

Page 23: ...23 Appendix Appendix FR Installation Information for EU66 ...

Page 24: ...01 CARBFILT4 UK IE UK IE VENT PACK 2 24 Installation You can choose two type of installation Ducted option Recirculation option ...

Page 25: ...02 DIM B DIM B MIN 750mm MIN 650mm 170 122 34 170 90 Gas Electric MAX 735 25 ...

Page 26: ... 12 x 2 10 x 6 03 04 Maximum gap between top 2 holes and middle 2 holes can be no more than 735mm dependant on ceiling height 12 x 2 03 2mm 2mm 2mm 10 12 03 12 735 26 ...

Page 27: ...ensuring not to over tighten as this may cause damage to the glass 09 07 x 4 08 x 4 11 x 4 Place glass onto the cooker hood frame and connect the two plastic male female plugs for the LED perimeter lighting Adjust the glass to suit so the four holes in the glass align with the hood chassis ...

Page 28: ...07 08 28 hood Replace the aluminium Filter 12 x 2 ...

Page 29: ...09 10 13 x 2 06 13 06 29 Fix the Ducting Tube 125 or 150 using tape or clamp Vent Pack 2 UK IE x 1 Fix the Collar and the reducer if required ...

Page 30: ...11 12 30 02 13 02 x 1 13 x 2 ...

Page 31: ...13 31 Remove the Protector film For recirculating option refer to Care and maintenance section Note For electrical connection see Technical and legal information section ...

Page 32: ...rgy Consumption AEChood 106 kWh a Time increase factor f 1 6 Fluid Dynamic Efficiency FDEhood 10 7 Energy Efficiency Index EEIhood 104 8 Measured air flow rate at best efficiency point QBEP 159 2 m 3 h Measured air pressure at best efficiency point PBEP 136 Pa Maximum air flow Qmax 277 6 m 3 h Measured electric power input at best efficiency point WBEP 56 0 W Nominal power of the lighting system W...

Page 33: ......

Page 34: ......

Page 35: ......

Page 36: ...Apelson Appliances UK Limited Unit 3 Normandy Landings Pope St Castleford WF6 2AG GB IE ...

Reviews: