K
EYPAD
L
OCK
Operating and Programming Instructions
There are two ways to open Design House Keypad Locks.
- Enter a valid 6-digit password; the green indicator light will go ON; use the lever or knob
to open the latch within 5 seconds.
- Manual override keys (for emergency use).
IMPORTANT
1. The factory set Master Code is 111111 . Pl ease ch ange th e M aster Pa ssword to a ne w
6-digit Master Code on the initial use.
2. The Design House Keypad Entry Lock holds 300 User Passwords.
3. The Design House Keypad Entry Lock makes several sounds:
- Three short beeps indicate an incorrectly keyed code. Door will not unlock.
- One long beep indicates a correctly keyed code. Open the latch within 5 seconds to open
the door.
Code Definitions
Master Code
= 6 digits. Required for making changes and additions to all codes. Factory
set Master must be changed the 1st time the lock is used for increased security.
Property owner/manager should keep this information confidential.
User Number
= 3 digits. Identifies the user. Property owner/manager should keep a log of
User Numbers.
User Password
= 6 digits. User enters this code on the keypad to gain entry into building.
Programming/Changing Codes
Changing the Master Code (initial use)
Press: ## + Factory Set Master Pa *** + New Master Pa New Master
Password
Press: ## + Master Pa #** + 3-digit User 6-digit User Pa 6-digit User
Password
Example: To add User Number 005 with User Password 123456, press: ## + Master
Pa #** + 005 + 123456
Adding a User Password
Deleting a User Password
Press: ## + Master Pa *#* + 3-digit User 3-digit User Number
Changing a User Password
Press: ## + User Password to be c *** + New User Pa New User Password
Enabling Passage Function
(Press any key to open the door)
Press: ## + Master Pa ### + ###
Disabling Passage Function
(keeps door in LOCKED state; opened with valid User Passwords)
Press: ## + Master Pa ### + ###
USERS-To Open the Lock
Press: User Password. After green light goes ON, press lever or rotate knob to open
door within 5 seconds.
In case of loss of user records or other need to RESET all
passwords
Dismantle the Keypad Lock assembly. Press the RESET button on the inside of the
Exterior Panel.
Lock will return to factory set Master Code. Change to new Master Code. Program all
new User Numbers and User Passwords as listed above.
Page.7
Page.8
R