This Manual is applicable to Soft LED2 XL Vari-White
Revised on June 2020
ILT ITALY srl
Via Cancelliera, 10/a
00041 Albano Laziale (Rome) Italy
tel. +39 06-902901 fax +39 06-90231051
www.desisti.it
3.
POWER AND DMX DAISY CHAIN
The SOFT LED permits both POWER and DMX DAISY CHAIN.
In fact each Fixture is respectively equipped with:
For DMX:
•
1 XLR5 pin Panel Mount Male (DMX IN)
•
1 XLR5 pin Panel Mount Female (DMX OUT)
For Mains Supply
•
1 20A Powercon NAC3MPA BLUE (POWER IN)
•
1 20A Powercon NAC3MPB WHITE (POWER OUT)
It is recommended to Daisy Chain a Max of 10 fixtures, even if the limitations imposed by DMX Standards are for an higher q.ty of units and even
if the Powercon Connections are rated for 20A max.
4.
SAFETY INSTRUCTIONS
Ü
Professional use: This luminaire has been designed for professional use and must be operated by qualified personnel only. Not for residential
use.
Ü
Grounding: WARNING: THIS LUMINAIRE MUST BE GROUNDED
Ü
WARNING: Disconnect Power CORDS before
any maintenance work or opening the FUSE HOLDER.
Risk of serious injury.
Ü
Electrical connections: IMPORTANT The cores in this mains lead are colored in accordance with the following code:
Europe
America
Ground
Green & yellow
Green or green & yellow
Neutral
Blue
White
Live
Brown
Black
In case the colors of the cores do not correspond to the colors of the connection points on your plug, please proceed as follows:
•
the green or green and yellow core must be connected to the connection point marked with the letter E or with the symbol or colored
in green or in green - yellow;
•
the blue (or white) core must be connected to the connection point marked with the letter N or colored in black;
•
the brown (or black) core must be connected to the connection point marked with the letter L or colored in red.
Ü
Working Position
Lighting fixture: Max. Tilting
±
90° from horizontal
Ü
Ambient Temperature,
t
a
at the place of installation and Storage
Minimum 10°C, m40°C
Ü
Humidity
at the place of installation and Storage
25-80% (not condensing)
Ü
Minimum distances from inflammable
surfaces
Top
Back
Sides
Front
0,2 m.
0,1 m.
0,1 m.
0,75 m.
The luminaire should never be OPERATED close to inflammable materials. The ones indicated in the above table are the minimum distances
recommended. Other requirements for safe use are:
A.
Do not cover the apertures of the luminaire housing. They are essential for correct ventilation.
B.
Use only original accessories and spares from De Sisti Lighting.