Blast chiller Service Manual
13
Rev 07/04/2015
Parameter Description
Factory Value
P22
defrost type
0 = electric (defrost on relay)
1 = hot gas (defrost compressor and relay on)
2 = air (evaporator fan on)
2
P23
defrost end temperature (with reference to the evaporator
probe)
8
P24
maximum defrost duration
10
P25
defrost interval during storage; see also P26
0 = intermittent defrosting will never be activated (only the first
will be activated)
6
P26
first defrost delay from start of storage; see also P25
1
P27
defrosting at start of chilling and freezing
1 = YES
0
P28
drip-drain duration
2
P29
resetting of compressor protections at start of defrosting (only
if P22 = 1)
1 = YES
0
P30
elapsed time between the defrost request and switching on the
compressor (only if P22 = 1 and providing that the compressor
is off when the defrost is requested); see P31 (7) (8)also
30
P31
elapsed time between the defrost request and activation of the
solenoid valve (only if P22 = 1 and on condition that the
compressor is off when defrosting is requested); see also P30
0
P32
temperature above which the evaporator fan is switched off
during storage (with reference to the evaporator probe)
3
P33
P32 differential
1
P34
evaporator fan activity during defrosting (only if P22 = 0 or 1)
0 = on
1 = off
0
P35
evaporator stop time after dripping
3
P36
temperature above which the evaporator fan is switched off
(with reference to the cabinet probe)
90
P37
effect caused by activation of microport input on evaporator
fan
0 = no effect
1 = the evaporator fan will be switched off
1
P38
microport input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
1
P39
micro port input alarm delay
0
P40
high pressure input contact type
0 = NA (input active with contact closed)
1 = NC (input active with contact open)
0
P41
high pressure input alarm delay
120
Summary of Contents for GBC-15
Page 1: ...Service Manual Blast Chiller...
Page 2: ...Rev 07 04 2015 2...
Page 3: ...Blast chiller Service Manual 3 Rev 07 04 2015...
Page 32: ...Rev 07 04 2015 32...
Page 40: ...Rev 07 04 2015 40...
Page 50: ...Rev 07 04 2015 10 20 10 0 10 20 30 40 kOhms C kOhmsVsTempChart NTC 10kOhms 25 C ZOOM...
Page 57: ...Blast chiller Service Manual 17 Rev 07 04 2015 L1 L2...
Page 91: ...Blast chiller Service Manual 51 Rev 07 04 2015 6 SCHEMATICS 6 1 SCHEME OF COMPONENTS...
Page 97: ...Blast chiller Service Manual 57 Rev 07 04 2015...
Page 100: ...Rev 07 04 2015 60...