4.3.2 5 shelves units
These models do not come equipped with a sliding base plate for the condensing unit. All
the components are mounted directly to a base plate which is part of the unit’s structure.
The procedure for accessing these components is different from that for the model
previously described. However, the first eight steps are the same.
a) Follow the instruction from a) to g) at the previous paragraph
b) Unscrew the 8 bolts from the bottom of the cabinet (4 each side)
c) In the front side, lift the cabinet up enough so the drain duct will clear the condenser
coil.
LIFT THE CABINET UP.