Blast chiller Service Manual
41
Rev 07/04/2015
4.4.2 Accessing the Evaporator
Remove the screws that attach the hinged panel. Lift the panel up and remove it.
4.4.3 Replacing the Temperature Sensing Probes
Cabinet Probe
Remove the metal guard
Cut and remove the plastic mounting tie.
remove the probe wires from the main control terminals.
Cut off the probe bulb and all wire ties.
Attach the wires from the replacement probe wires to the wires of the existing probe.
From the controller side, pull the wire of the existing probe to route the new probe wires
correctly.
Attach the wires to the Main Board.
mount the probe into position.
replace any wire ties.
reinstall the guard.