Error
Description
Validation / Action
At start-up, after
switch-off the white
LED, the LED flashes
8 times (red color)
(3 flashes/second).
Main configuration has
been restored from the
backup configuration.
User not affected by this issue during normal
work.
If the user was updating the configuration of
the tool with the Speed Setting Module, it is
recommended to check the speed of the tool.
This error appears if the main configuration has
been restored after corruption.
Permanent flashing of
the LED (red color)
(6 flashes/second).
The tool switched to default
setting.
The tool can be used but only with the default
parameters.
Speed and counters may be affected.
It is recommended to check the parameters
with the Speed Setting Module. If the problem
persist when the battery is plugged in, it is
recommended to replace the electronic board.
Permanent flashing of
the LED (red color)
(3 flashes/second).
All configurations have
been corrupted.
Tool blocked.
This alarm appears if the memory chip is out of
order.
The electronic board must be replaced.