461933
Issue no : 08
Series : C
11/2016
18 / 64
●
Position the HCU in (3).
●
Set the gap between (6) and (7) to a distance
as required above the work piece.
●
Unscrew (8) away from the HCU to adjust the
resistance within the HCU to the minimum.
●
Fully open the Figure 3 (13).
●
Close Figure 3 (11).
●
Connect the air supply and press Figure 3
(6).
●
Adjust Figure 3 (11/13) to give required
advance, retract feeds for the operator.
● Use Figure 5 (1) for the final depth
adjustment.
●
Lock using Figure 5 (9).
●
Carry out a set of trial drillings to determine
the ideal advance and HCU settings using
Figure 3 (11).
SETTING TAPPING OPERATION
Note 1
: lt is important that the advance
rate of the tool is set to match the pitch
of the thread which is to be tapped.
An incorrect advance rate will result in
a deformed thread, this will be more
noticeable in plastics or light alloy
materials.
Note 2
: The retract rate should be set to
withdraw the tap at a slightly faster rate
than it advanced, this will ensure a clean
withdrawal.
●
Mount a tool, with the selected tap securely
retained in the chuck, above a test block to
carry out sample tapping operations.
●
The end of the tap MUST be at least 14mm
(9/16in) above the test block, to allow for the
tapping head reversing engagement travel.
●
Set the gap between Figure 5 (2) and (1) to
equal the tapping depth PLUS the distance
the tap is above the work piece.
●
Adjust Figure 3 (11/13) to give the required
advance, retract feeds for the operation.
●
Carry out a trial tapping operation and inspect
the finished thread form, adjust as necessary
Figure 3 (11/13) and repeat until information
in NOTES 1 and 2 are satisfied.
SERVICING REQUIREMENTS
General Notes
Use the following lubricants:
●
Grease - molykote Longterm W2 for splines
and guide rod.
●
Grease - Molykote PG75 Plastislip for
O-Rings.
●
Grease - BP FGOOEP for Cylinder bore.
Cleaning
Requirements:
(1) Container to immerse components.
(2) Good quality clean paraffin.
●
Soak the components in the container
containing the paraffin.
●
Ensure full immersion, agitate components to
ensure that air passages are flushed through.
●
Remove components from the container,
thoroughly dry and blow through air passages
to remove moisture.
●
Place components in an air tight container
until required for assembly.
● Dispose of the dirty paraffin in accordance
with health and safety regulations.