A
BOUT
T
HIS
M
ANUAL
LAC/LFC Series Oven
Owner’s Manual
14
Version 1.12
Copyright © 2018 by Despatch Industries.
All rights reserved. No part of the contents of this manual may be reproduced, copied or transmitted in any form or by any
means including graphic, electronic, or mechanical methods or photocopying, recording, or information storage and
retrieval systems without the written permission of Despatch Industries, unless for purchaser's personal use.
*The overcurrent protection means provided by the building mains supply circuit shall be a
branch circuit rated protection device.
1.5.5. Temperature
LAC-8 Model Number
LFC
1-38
LFC
2-12
1-38
120V
1-38
240V
LAC
1-67
LAC
2-12
LAC
2-18
Time to Temperature
40
°
C
– 100
°
C
(approximate minutes
40
°
C
– 200
°
C
With dampers closed and no load) 40
°
C
– 260
°
C
2
9
12
9
35
60
6
25
45
6
26
40
7
18
35
5
20
45
Recovery Time - Door Open
100
°
C
One Minute (approximate
200
°
C
minutes with no load)
260
°
C
N/A
N/A
1
6
14
1
4
8
1
3
5
1
6
9
1
4
8
Temperature Uniformity at
100
°
C
3F
§
200
°
260
°
± 2 %
of set-point
± 1
° C
± 2
°
C
± 2.5
°
C
Operating Range with 20
°
C Ambient
40
°
C
– 260
°
C
Control Stability
± 0.5
°
C per 5
°
C change in ambient
Repeatability
± 0.5
°
C
1.5.6. LAC-8 Series Oven Environmental Operating Conditions
The LAC-8 Series oven is for indoor use. Table 1 provides the operating conditions.
§
Figures are based on actual tests in an empty oven. Uniformity can vary slightly depending on unit and
operating conditions.
LFC2-12-8
240
29.2
50/60
1
6
None, Hardwired.
Branch circuit rated device 40A.*
208
33.5
6
None, Hardwired.
Branch circuit rated device 50A.*
LAC2-18-8
240
24.2
50/60
1
4.8
None, Hardwired.
Branch circuit rated device 30A.*
208
27.8
4.8
None, Hardwired.
Branch circuit rated device 35A.*