DS7080iP-32 Reference Guide Copyright © 2001 Detection Systems, Inc. P/N 39818D Page 19
7.5
Automatic Arming
To inform occupants that the system is about to arm, a pre-arming period will begin 15 minutes before the system arms automatically. If
programmed by the installing company, the keypad sounders, and any outputs programmed to follow the keypad sounders, will pulse five
times every minute. During the last five minutes before arming, these sounders will be on steady. Once per minute the DS7447 keypad will
read, “Arm in nn min./PIN + OFF - extend.”
Automatic Arming will affect only the partitions you have access to.
Each partition can be programmed to automatically arm once per day. To program the Automatic Arming Time, perform the following:
Setting the Automatic
Arming Time
Notes
Enter a [Master PIN] + [#] [0]
Setting the Automatic Arming Time can only be performed with a Master Code PIN.
Enter a [1]
Enters the Automatic Arm Setup programming
Enter the partition number;
Press [#] to exit
The program will prompt you to enter partition 1 or 2 if the system is partitioned and if the use has
access to both partitions. If the system is not partitioned or if the user has access to only one
partition, this selection will not appear.
In a non-partitioned system, the display will automatically go to Sunday.
The user will only be allowed to program the partitions to which they are assigned.
Enter a Time for each day
Enter in [0] [1] [0] [0] [#] format
The display will start with Sunday. It will read “Sunday – nn:nn”
Enter the time in 24-hour format. You may move the cursor left or right by pressing the “A” (Fire) or
“C” (Panic) keys. When you have completed the time entry press [#]. The display will then advance
to the next day. You may exit the Set Auto Arm Time Mode at any time by pressing [*] once. The
system will also exit the Auto Arm Time Mode after the time is programmed for Saturday.
Samples of times:
12 midnight = 2400#
12 noon = 1200#
12:01am = 0001#
12:01pm = 1201#
1:00am = 0100#
1:00pm = 1300#
Disabled = 0000#
Note:
The panel time and date must be set in order for this feature to work properly.
7.6
Delayed Automatic Arming
This section explains how to delay the Automatic Arming Time.
To inform occupants that the system is about to arm, a pre-arming period will begin 15 minutes before the system arms automatically.
If programmed by the installing company, the keypad sounders, and any outputs programmed to follow the keypad sounders, will pulse
five times every minute. During the last five minutes before arming, these sounders will be on steady.
Once per minute the DS7447 keypad will read, “Arm in nn min./PIN + OFF - extend.”
Delayed Automatic Arming will affect only the partitions you have access to.
To extend the Automatic Arming of the system during the automatic arming pre-arming period, perform the following steps:
Extending Automatic Arming *
What Will Happen
Enter a [PIN]
Press [OFF]
The arming time will be extended 30 minutes. A new
pre-arming periof will begin 15 minutes prior to the
new automatic arming time.
* = To extend the Automatic Arming at any time, use the Delayed Arming feature in the “Setting Dealyed Arming” seciton.
Note:
The keypad volume setting also applies to the Auto Arm tone.
Note:
The panel time and date must be set in order for this feature to work.