Page 20 P/N 39818D Copyright © 2001 Detection Systems, Inc. DS7080iP-32 Reference Guide
7.7
Error Displays
Control panel problems are indicated by a flashing green Power Light.
The DS7447 display will also read “Control Trouble, Enter [#] [8] [7].” The DS7445 will only flash the green Power Light.
The Error messages may only be read when the control is disarmed.
Contact your installing company if the problems persist.
1. DS7447 - “AC Power Failure”:
DS7445 - LED 1 turns on steady:
There is a power failure and the panel is operating on backup
battery.
2. DS7447 - “Battery Trouble”:
DS7445 - LED 2 turns on steady:
If the system has just been through a power failure, wait at
least two hours for the battery to recharge, then enter [PIN]
+ [System Reset] to perform a battery test.
3. DS7447 - “Communicator Err”:
DS7445 - LED 3 turns on steady:
The communicator failed to communicate with the central
station.
4. DS7447 - “System Fault”:
DS7445 - LED 4 turns on steady:
Internal error in the control circuitry or optional circuitry. These
faults are displayed as follows:
5. DS7447 - “Keypad Fault”:
DS7445 - LED 5 turns on steady:
One of the keypads is not responding to the control panel.
6. DS7447 - “Aux Power Fault”:
DS7445 - LED 7 turns on steady:
The auxiliary power has been shorted.
7. DS7447 - “Zone Trouble XX”:
Zone XX (number) is not responding to the control panel or is
not ready. This may also be displayed during power-up (if so,
ignore).
* = If in “Residential Mode”, a PIN is not required for these
commands.
** = Battery Trouble and Communicator Err displays must be
cleared by the [System Reset] command sequence even after
the problem has been remedied. These displays will not self
clear. All the other error displays will self clear from the
keypads once the problem has been remedied.
8. DS7447 - “Pt Exp Mssng XXX”:
DS7445 - LED 8 turns on steady:
The EX8 Zone Expansion Module for Address XXX is missing,
defective or not communicating to the Options bus.
9. DS7447 - “Pt Exp Tamper XXX”:
DS7445 - LED 8 turns on steady:
The EX8 Zone Expansion Module for Address XXX has a tamper
condition.
10. DS7447 - “Pt Exp Fault”:
DS7445 - LED 8 turns on steady:
The EX8 Zone Expansion Module(s) has had a DC overcurrent
fault.
11. DS7447 - “Keypad Tamper”:
DS7445 - LED 6 turns on steady:
One of the keypad housings has been opened.
7.8
Remote Program Dial-out and Answer
Type of Function
Command Sequence *
What Will Happen
Remote Program Dial-Out **
[PIN] + [#] [8] [3]
The panel will call the remote
programmer.
Remote Program Answer
[PIN] + [#] [8] [6]
The panel will answer a call from
the remote programmer.
This chart will help you to call or answer the Remote Programmer.
* = If in “Residential Mode”, a PIN is not required for these commands.
** = Phone numbers 1 and 3 must be programmed. Phone #1 Account Code must be programmed.
Action Desired
Read the Error Display
when the green Power Light
is flashing.
Clear Error Display**
Caution: Clear the error display
only on the advice of your installing
company or if you are certain the
problem has been remedied.
Command Sequence*
[PIN] + [#] [8] [7]
[PIN] + [System
Reset]
or
[PIN] + [#] [8] [7] [*]