9.3
Address 003 - User Controls
User Controls are used to determine if there is a keypad audible during the exit time,
if the audible devices are tested upon arming the system, whether the Trouble Zone
is Normally Open or Closed and if the PIN numbers are 4 or 6 digits in length.
• Keypad Audible During Exit will activate the keypad sounder (and any outputs
programmed to follow the keypad sounder) once every 5 seconds during the exit
delay. At 10 and 5 seconds remaining, the sounder will activate 3 times. The Keypad
Audible During Exit also determines if the sounders will activate during the Auto
Arm period.
• To inform occupants that the system is about to arm, a pre-arming period will begin
15 minutes before the system arms automatically. If programmed, the keypad
sounders and any outputs programmed to follow the keypad sounders will pulse
five times every minute. During the last five minutes before arming, these sounders
will be on steady. Once per minute the DS7447 keypad will read, “Arm in nn min./
PIN + OFF - extend.”
Automatic Arming will affect only the partitions the user has access to.
If “Six Digit PINs” has been selected and the PIN numbers have been entered, changing to “Four Digit PINs” may cause PIN
entry errors. Changing from 6 to 4 digit PINs will retain the first 4 digits of the existing PINs and drop the last two digits.
Example: 123456 will become 1234. If two or more six digit PINs have the same first four digits, a PIN conflict will exist if
changed to four digits.
Changing from four to six digit PINs will add two zeros to the end of the existing PINs. Example: 1234 will become 123400.
It is recommended that when changing the PIN length that all PINs be reprogrammed.
9.4
Address 004 - Programmer and Master Codes
The display will not show the values entered but the cursor will move to indicate the digit you are changing. If the 4 Digit
mode is selected in Address 003 only digits 1-4 for the programmer’s PIN and 7-10 for the Master PIN need to be changed.
If 6 digits is selected in Address 003 you must enter digits 1-6 for the programmer’s PIN and 7-12 for the Master PIN. You
may move the cursor left by pressing the “C” (Panic) key or right by pressing the “A” (Fire) key. You can change individual
digits in the PIN numbers by moving the cursor to the position and entering a new number.
The use of four or six digits depends on the PIN Length as selected in digit 4 of Address 003. If four digits is selected in Address
003, then only the first four digits of the Programmers and Master PINs will require programming.
9.5
Address 005 - Cross-Zoning
Cross-zoning programming determines which zones may be cross-zoned with each other. Only zones 1-8 may be cross-zoned.
9.6
Address 006 - Trip window
Cross-zoning Trip Window Time programming defines the number of seconds for the Cross-zone Window. If 000 is used the trip window
will be the duration of the arm cycle of the crossed non-24 hour zones. If they are 24 hour zones, then the duration is 24 hours.