Page 28 P/N 39818D Copyright © 2001 Detection Systems, Inc. DS7080iP-32 Reference Guide
9.12 Address 012 - Phone Controls
DEFAULT 1 0 0 0
0
0
TONE/PULSE
0 = Dial Pulse on all Phone Numbers
1 = Dial Tone, switch to Pulse if required
2 = Dial Tone on all Phone Numbers*
CALLBACK
0 = Disable Remote Programmer Callback
1 = Enable Remote Programmer Callback
AUTO ANSWER RINGS - ARMED
0 = Do not answer
1-F = Answer on rings (odd numbers
Bypass Answering Machine)**
AUTO ANSWER RINGS - DISARMED
0 = Do not answer
1-F = Answer on rings (odd numbers
Bypass Answering Machine)**
DIALER DELAY OF 15 SECONDS ON
NON-24-HOUR BURGLAR ALARMS
0 = No Dialer Delay
1 = 15 Second Dialer Delay
DIALER DELAY OF 15 SECONDS ON
24-HOUR BURGLAR AND FIRE ALARMS
0 = No Dialer Delay
1 = 15 Second Dialer Delay
0
WDSRP BAUD RATE
0 = 110 Baud
1 = 300 Baud
*
Required on PBX systems.
** The letters used for the ring counts are:
A = 10 rings
B = 11 rings
C = 12 rings
D = 13 rings
E = 14 rings
F = 15 rings
9.13 Address 013 - Partition 1 Account Codes
1) Account codes are programmed from left to right. If programming a 3-digit Account Code, the last digit of the code must be zero (0).
2) 0000 is not a valid Account Code.
3) If you program the Account Code with an “A” (*0), the panel will send a zero (0) in its place.
4) If one of the Account Codes for Partition 2 or Parition 1 Phone #1 is programmed as 0000, then the panel will use the code programmed
for Partition 1-Phone #1.
9.14 Address 014 - Partition 2 Account Codes
See Note in Section 9.13.