Page
4
of
17
UNINSTALLING DEVICE
To facilitate maintenance procedures, the device must be removed from the door.
Verify the functionality of the device before removing any hardware. Look for any misaligned
components and missing or loose screws. Record the current status of the device, as this could
help plan a maintenance program that will keep the device working properly and extend its
service life. Use good quality tools with new tips to prevent damaging screws.
STEP 1.
Open door to expose mounting screws for Strike, Center Case Cover and End Cap. Door
must be held in this position to allow removal of all necessary hardware.
99 Strike is mounted
with 3 screws.
94 Strike is mounted
with 2 screws.
98 Strike is mounted with 2
screws; the shield uses 4.
End cap is mounted with 2
screws.
(EC1 shown).
Center case cover is mounted
with 2 screws on strike side and 2
screws on pushpad side (10
Series shown).