Endcap Mounting
Bracket
CD (Cylinder Dogging)
MORTISE CYLINDER INSTALLATION
Mortise Cylinder
Figure A1
Fillerplate
Dogging
Assembly
Spacers
Cylinder Installation
Endcap
104887 Page 15
Follow steps "a" through "g" for CD installations
a. Remove endcap and endcap mounting bracket.
b. Remove fillerplate.
c. Remove and discard shipping insert and nut. Loosen (2) screws from dogging assembly.
d. Install mortise cylinder (sold separately) with large hex nut provided.
e. Trial fit dogging assembly. If cylinder is too short, remove spacers as necessary and reattach them
under the (2) screw heads. Fasten the (2) screws to the rest of the assembly.
NOTE: The key should easily turn in both directions.
f. Rotate key counterclockwise
g. Assembly complete. Continue with Panic Hardware instruction.
1
L
2
Check for device and door
frame clearance.
If no cut-off needed,
proceed to the next page.
Cut fillerplate and
extrusion STRAIGHT &
SQUARE to desired
length and deburr
Minimum
Fillerplate
Length
Slide endcap assembly
onto extrusion
Secure with tape
before cutting
CAUTION:
CHECKING FOR DEVICE CLEARANCE
(Cut-Off procedure if required)
Type
Length (L)
2-1/2"
LD
3"
HD/CD
For aluminum Advantex finish cutdown applications:
After cutting, the baseplate extrusion can be reversed to place the cut end inside the head cover. To do so, loosen the
setscrew inside the aluminum baseplate extrusion and slide extrusion out, reverse, & slide back in. Tighten setscrew.
Mortise Cylinder with
standard Yale cam
required
.715"
.313"
Cylinder nut socket
p/n 103779
(sold separately)
10g
10h