Introduction

The

RTD-150T

is a 10" touch screen

repeater

.

When connected to an addressable panel, it
allows you to easily identify

events by displaying

them by type

, and to perform

actions

on the

panel, locate events on

maps

and send

informative

emails

.

Hardware

Power supply:

Micro USB connector:

for 5 Vdc supply (inc)

Power strip:

for 12-24 Vdc power supply

Connection to the panel :

USB-RS-485 converter (inc)

: connect it to the unit's

USB hub and the panel's Modbus connection.

Connection to an IDR-

TS’s

IP network:

It is possible to create a network of RTD-150T and
RTD-150E repeaters.

Wi-Fi connection

802.11 b/g/n (inc)

Ethernet connection

through a

USB-RJ45

converter

(optional)

Configuration

The RTD-150T can be configured on the

touch screen

or

through its

web server.

1-On the touch screen:

+

password level 3

+

SYSTEM

tab

On the touch screen you configure the network options,
communication with the panel, the sound options,
emails, zone filters, etc. After changing the configuration,
press

Reboot

.

2-Through the web server:

Here you update the firmware and perform backups and
restores. To access it: using a browser on a computer that
is connected to the same network as the RTD-150T,
enter:

http://IP of unit

Ip of the unit:

By default, the RTD-150T is supplied with

the Wi-Fi connection enabled and the Ethernet disabled.
To connect the unit to a Wi-Fi network, on the

touch

screen

go to

SYSTEM

configuration and press the

CONFIGURACION

button.

In the WLAN section, select the network that you want to
connect the unit to and configure the password. Return
to the program, leave the configuration screen and then
re-enter. The unit will show the assigned IP.

Networked units

You can connect multiple repeaters in a single

installation. Each installation will always have a

master

unit and the rest will be

slaves

.

The

master

is the unit that will be connected to the

panel; you have to configure its connection parameters
with the panel. The other units will be

slaves

and you have

to configure the

master

unit's IP and port for them.

To

monitor

the connected units, they must

ALL

be

assigned a name under the

Repeater Name

option in the

SISTEMA (SYSTEM) tab in Configuration .

And on the master unit, you must enter the names

(separated by commas) under the option

List of names of

repeaters to be monitored

.

Areas, maps and devices

Maps are added by connecting a pen drive to one of

the unit's USB connectors. The pen drive will contain the
maps on its root directory. To add them on the

Zones/Maps

configuration tab, press

Upload maps

.

-Areas:
-

These are configured on the

screen Zones/Maps

tab.

-Areas can be associated with one of the panel's

zones

or they can be used to

connect maps

.

-To

locate the area

on a

map

, press

Define on map

and

mark the corner points of the sector that will form the
area. It is possible to draw more than one sector for an
area. To do this, press

New sector

.

-When you have finished, press

Save

.

-Devices:

-

These are configured on the

screen Devices

tab.

-For each device, configure the description, associated

area, type and model of device, the device's
Panel/Loop/Point and the icons associated with its
normal, alarm and fault statuses.

-You must also locate the device within the associated

map, by pressing

Place

. A sliding button allows you to

change the size of the device.

-When you have finished, press

Add

.

User levels

Level 1:

No password. Allows you to stop the RTD-

150E's warning sound by pressing the screen.

Level 2:

User password

1111

. Allows you to access the

alarm panel's actions menu:

Sounders On

,

Sounders

silence, Silenced buzzer and Reset

Level 3:

Installer password

2222

. Allows you to access

the unit's configuration.