PRELIMINARY
MBE EGR TECHNICIAN'S GUIDE
4.3.2.2
146/1 — EGR Temperature below Normal
Perform the following steps to troubleshoot EGR temperature below normal:
1. Measure the resistance between pins 1 and 3 on the EGR temperature sensor.
See Figure 4-3.
Figure 4-3
EGR Temperature Sensor Pins and 55-Pin Connector Wires
[a]
If resistance is less than 3
, replace the EGR temperature sensor. Erase the fault
code memory and verify repairs. Refer to section 4.3.2.6.
[b]
If resistance is greater than 3
, go to step 2.
2. Measure the resistance between pin 28 of the 55-pin connector and pin 1 of the EGR
temperature sensor connector. See Figure 4-3.
[a]
If resistance is less than 3
, repair the short in the wire. Erase the fault code memory
and verify repairs. Refer to section 4.3.2.6.
[b]
If resistance is greater than 3
, go to step 3.
3. Measure the resistance between pin 22 of the 55-pin connector and pin 3 of the EGR
temperature sensor connector. See Figure 4-3.
[a]
If resistance is less than 3
, repair the short in the wire. Erase the fault code memory
and verify repairs. Refer to section 4.3.2.6.
[b]
If resistance is greater than 3
, go to step 4.
All information subject to change without notice.
(Rev. 5/05)
4-13
7SE940 0505
Copyright © 2005 DETROIT DIESEL CORPORATION
Summary of Contents for MBE 400
Page 1: ......
Page 2: ......
Page 4: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 103: ......
Page 105: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 121: ......
Page 122: ......