4. Check the resistance between pin 50 of the 55-pin connector and pin 1 of the EGR valve
connector. See Figure 4-4.
[a]
If the resistance is greater than 3
, repair the open circuit in the wire between pin 50
of the 55-pin connector and pin 1 of the EGR valve connector. If fault code s 146/2 is
no longer active, erase fault code memory and verify repairs. Refer to section 4.3.2.6.
[b]
If fault code s 146/2 is still active, go to step 5.
5. Check all contacts and connections. Remove corrosion as required. Check for active
fault codes.
[a]
If fault code s 146/2 is no longer active, erase fault code memory and verify repairs.
Refer to section 4.3.2.6.
[b]
If fault code s 146/2 is still active, go to step 6.
6. Check coolant usage.
[a]
If coolant usage indicates a leak, perform an
EGR Cooler Inspection.
Refer to appendix C, Service Information Letter 04
TS
- 38. Clean and replace
parts as indicated by inspection. Erase fault code memory and verify repairs.
Refer to section 4.3.2.6.
[b]
If coolant usage is normal and fault code s 146/2 is still active, contact the Detroit
Diesel Customer Support Center at 313-592-5800.
4-16
All information subject to change without notice.
(Rev. 5/05)
7SE940 0505
Copyright © 2005 DETROIT DIESEL CORPORATION
Summary of Contents for MBE 400
Page 1: ......
Page 2: ......
Page 4: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......
Page 103: ......
Page 105: ......
Page 107: ......
Page 108: ......
Page 109: ......
Page 110: ......
Page 111: ......
Page 112: ......
Page 113: ......
Page 114: ......
Page 115: ......
Page 116: ......
Page 117: ......
Page 118: ......
Page 119: ......
Page 121: ......
Page 122: ......