HOW-TO SECTION
NOTICE:
Required specifications for water,
ethylene glycol, propylene glycol,
inhibitor packages and inhibitor
concentration are included in
this section. To avoid possible
engine damage from inadequate
or over concentrated coolant,
this information should be read
thoroughly before the coolant is
replaced.
Coolant Fill Option
Product
Ethylene Glycol & Water + Corrosion
Inhibitors
1
DDC
Power Cool
Commercial Equivalent of DDC
Power
Cool
Fully Formulated TMC RP-329 Type A
Antifreeze & Water
Propylene Glycol & Water + Corrosion
Inhibitors
1
DDC
Power Cool
Plus
Ethylene Glycol & Water + OAT
Inhibitors
DDC
Power Cool
Plus
Water Only + Corrosion Inhibitors
2
Water + DDC
Power Cool
3000
Water Only + OAT Inhibitors
2
Water + DDC
Power Cool
Plus 6000
1
Preferred Coolant
2
Water-only coolant systems offer no freeze protection and should not
be used where ambient temperatures can fall to 0°.C (32° F).
Table 12 Initial Fill Coolant Options
EG & Water Plus SCA Inhibitor or
PG & Water Plus SCA Inhibitor —
These products are available as fully
formulated, phosphate-free, extended
service interval (ESI) coolants.
They are commercially available
from Detroit Diesel (recommended)
and other manufacturers as either
a concentrated antifreeze or as a
pre-mixed antifreeze. The pre-mixed
antifreeze is ready for use, while the
concentrated coolant must be mixed
with water prior to use.
102
All information subject to change without notice.
(Rev. 04/08)
DDC-SVC-MAN-0040 0704
Copyright © 2008 DETROIT DIESEL CORPORATION
Summary of Contents for MBE 900