MBE 4000 SERVICE MANUAL
17.2.3
Low Power Troubleshooting Chart
There are three basic checks that should be performed:
□
Check for active/historic codes. Refer to MBE DDEC Application/Installation Manual
(7SA825) Appendix A (fault codes). All causes need to be checked once the fault is
identi
fi
ed. Record faults on the Application For Adjustment (AFA) claim, if there is to
be a claim.
□
Check the VCU/PLD parameters, progressive shift settings, and torque limiting values.
Are they correct? Is proper rating applied? If vehicle is new, is it spec'd correctly?
□
Check that the dyno-measured power is within DDC speci
fi
cations as listed in Table 17-3
for minimum acceptable wheel HP data. Record data on AFA claim.
NOTE:
Service information letter instructions published following the date of this document
take precedence.
All information subject to change without notice.
(Rev. 2007)
6SE412 0702
Copyright © 2007 DETROIT DIESEL CORPORATION
From Bulletin 1–MBE 4000–07
17-11