DDEC IV TESTING
Power Loss Under Heavy Pull
With power loss under heavy pull and in extreme cold ambient conditions, the engine will operate
in
Condensation Protection
. During this mode of operation, the engine
boost
will be reduced
and there is no reduction of power. Operating in this mode is a normal operating condition
and will not affect engine life or performance.
NOTE:
Trucks operating with winter fronts will experience this condition less often. DDC’s
recommendations have not changed regarding winter front usage.
Perform the following steps for
Power Loss Under Heavy Pull
.
1. Check for diagnostic trouble codes. If Fault Codes are logged, diagnose the logged codes
fi
rst.
2. Visually inspect the air
fi
lter restrictions. If the air
fi
lter is clogged or dirty, replace the
air
fi
lter.
3. Visually inspect the air inlet hoses for soft or collapsed areas. If the air inlet hoses are
damaged, replace as necessary.
4. Visually inspect the air inlet for restrictions. If the air inlet has restrictions, clean as
necessary.
5. Visually inspect the entire length of the breather tube for kinks. If the breather tube has
kinks, repair as necessary.
6. Measure the fuel pressure under heavy loads.
[a] If the fuel pressure was spiking or decreasing, perform step 7.
[b] If the fuel pressure was not spiking or decreasing, testing is complete.
7. Remove the fuel pump.
[a] If the fuel pump is damaged, replace the fuel pump.
[b] If the fuel pump is not damaged, perform step 8.
8. Remove the fuel injectors and inspect for combustion passing the seat.
[a] If seats are damaged, replace as necessary.
NOTE:
The fuel injector may need to be replaced also.
[b] If the seats are not damaged, testing is complete.