Table 5: Airflow (CFM) - SUPREME with 1/3 HP motor
Furnace equipped with a 1/3 HP / 120 blower motor
Blower
External static pressure (inche of W.C.)
Speed
0,2
0,3
0,4
0,5
0,6
0,7
0,8
LOW
660
635
615
595
580
565
540
MED-LOW
840
815
800
775
750
715
670
MED-HIGH
1 025
1 010
995
975
945
900
860
HIGH
1 260
1 240
1 200
1 150
1 110
1 055
975
Furnace equipped with a 1/3 HP / 240 blower motor
Blower
External static pressure (inche of W.C.)
Speed
0,2
0,3
0,4
0,5
0,6
0,7
0,8
LOW
660
635
615
595
580
565
540
MED
840
815
800
775
750
715
670
HIGH
1 260
1 240
1 200
1 150
1 110
1 055
975
•Airflow values in cubic feet per minute (CFM) rounded to the nearest 5CFM
•Data taken with air filter in place.
Table 6: Airflow (CFM) - SUPREME with 1HP motor
Furnace equipped with a 1HP / 120 blower motor
Blower
External static pressure (inche of W.C.)
Speed
0,2
0,3
0,4
0,5
0,6
0,7
0,8
LOW
1 110
1 090
1 085
1 080
1 070
1 050
1 005
MED-LOW
1 455
1 430
1 410
1 400
1 380
1 355
1 320
MED-HIGH
1 865
1 830
1 800
1 740
1 705
1 665
1 605
HIGH
2 055
2 045
2 030
2 010
1 980
1 880
1 800
Furnace equipped with a 1HP / 240 blower motor
Blower
External static pressure (inche of W.C.)
Speed
0,2
0,3
0,4
0,5
0,6
0,7
0,8
LOW
1 030
1 030
1 030
970
950
935
900
MED-LOW
1 380
1 350
1 310
1 275
1 250
1 225
1 175
MED-HIGH
1 785
1 735
1 730
1 725
1 650
1 610
1 515
HIGH
2 230
2 199
2 110
2 030
1 900
1 815
1 730
•Airflow values in cubic feet per minute (CFM) rounded to the nearest 5CFM
•Data taken with air filter in place.
13