14
Table 6
Technical Specifications
154 Series, multi-position models
Firing rate (USGPH)*
0.90
1.10
0.90
1.10
Input (BTU/h)*
126,000
154,000
126,000
154,000
Maximum Heating capacity, (BTU/h)*
107,000
129,000
107,000
129,000
Heating temperature rise (Degr. F)*
Flue draft with chimney (inch of w.c.)
Overfire pressure with chimney (inch of w.c.)
Flue pressure with direct vent (inch of w.c. - no wind)
Overfire pressure with direct vent (inch of w.c. - no wind)
BECKETT BURNER; MODEL NX (Chimney or DV)
Burner tube insertion length (inches)
Head type
Nozzle (Delavan)
0.75 - 60B
0.90 - 60B
0.75 - 60B
0.90 - 60B
Minimum and Maximum pump pressure (PSIG)*
145
150
145
150
Head/Air setting
3,5
4
3,5
4
AFUE % (From CSA B212 standard and Canadian regulation)**
‡ 87,0%
‡ 85.6%
‡ 87,0%
‡ 85.6%
AFUE % (From ASHRAE 103 standard and US regulation)**
‡ 85.3%
‡ 85.1%
‡ 85.3%
‡ 85.1%
RIELLO BURNER; MODEL 40-F5 (Chimney)
Burner tube insertion length (inches)
Nozzle (Delavan)
0.75 - 70A
0.90 - 70A
0.75 - 70A
0.90 - 70A
Minimum and Maximum pump pressure (PSIG)*
145
150
145
150
Combustion air adjustment (turbulator/damper)
1.5 / 2.25
2.5 / 2.75
1.5 / 2.25
2.5 / 2.75
AFUE % (From CSA B212 standard and Canadian regulation)**
‡ 86.6%
‡ 85.3%
‡ 86.6%
‡ 85.3%
AFUE % (From ASHRAE 103 standard and US regulation)**
‡ 86.0%
‡ 85.0%
‡ 86.0%
‡ 85.0%
RIELLO BURNER; MODEL 40-BF5 (Direct vent DV)
Burner tube insertion length (inches)
Nozzle (Delavan)
0.75 - 70A
0.90 - 70A
0.75 - 70A
0.90 - 70A
Minimum and Maximum pump pressure (PSIG)*
145
150
145
150
Combustion air adjustment (turbulator/damper)
1.0 / 3.75
3.0 / 4.25
1.0 / 3.75
3.0 / 4.25
AFUE % (From CSA B212 standard and Canadian regulation)**
‡ 86.4%
‡ 85.7%
‡ 86.4%
‡ 85.7%
AFUE % (From ASHRAE 103 standard and US regulation)**
‡ 86.1%
‡ 85.0%
‡ 86.1%
‡ 85.0%
Volts - Hertz - Phase
Rated current (Amps)
Minimum ampacity for wire sizing (Amps)
Max. fuse size (Amps)
Control transformer (VA)
External control power available Heating (VA)
Cooling (VA)
Heating blower speed at 0.25" W.C. SP
MED-LOW
MED-HIGH
Heating blower speed at 0.50" W.C. SP
MED-LOW
MED-HIGH
Motor (HP) / number of speeds
Blower size (diam. x width)
Overall dimensions (width x depth x height)
Supply air opening (width x depth)
Return air opening (width x depth)
Filter size
Shipping weight Lbs/Kg
Air conditioning, maximum output (tons) at 0.5" W.C. SP
UNITS WITH 1.0 HP 4-SP. MOTOR
UNITS WITH 1.0 HP ECM MOTOR
RATING AND PERFORMANCE
55 - 75 Degr. F
60 - 72 Degr. F
-0.06 to -0.035
-0.06 to -0.035
-0.035 to +0.045
-0.035 to +0.045
+0.05 to +0.16
+0.05 to +0.16
+0.06 to +0.22
+0.06 to +0.22
NX50LC
NX50LC
1 3/4''
1 3/4''
6 Slots - LC head
6 Slots - LC head
F5 WITH ELECTRIC AIR DAMPER
F5 WITH ELECTRIC AIR DAMPER
2 3/4''
2 3/4''
BF5
BF5
2 3/4''
2 3/4''
ELECTRICAL SYSTEM
115 - 60 - 1
115 - 60 - 1
16,9
15,7
19,5
18,1
20
20
40
40
40
40
30
30
BLOWER DATA
See the ECM air flow table
1.0 HP / 4 speeds
1.0 HP / ECM (with inductor)
12'' x 10'' (tight housing)
12'' x 10'' (tight housing)
GENERAL INFORMATION
25'' x 28 1/2'' x 48''
25'' x 28 1/2'' x 48''
20'' x 22''
20'' x 22''
23'' x 23''
23'' x 23''
5.0
5.0
24'' x 24'' x 1"
24'' x 24'' x 1"
200 / 90
200 / 90
Summary of Contents for AMP154SD