background image

 

 

23 

Table 11 

Parts list with variable speed motor (ECM) 

 

ITEM

PART #

DESCRIPTION

COMMENTS

1

B03820

HEAT EXCHANGER

Heat exchanger only

2

J06L002

SEAL STRIP,  DIA 1/8 x 25'

3

B03856-01

FRONT PANEL ASSEMBLY

Panel, insulation and labels included

4

B03866

FRONT PANEL INSULATION

5

B03835-01

BAFFLE, LATERAL

6

B03855-01

SIDE PANEL ASSEMBLY (RIGHT)

Panel, insulation and baffle included

7

B03865

SIDE PANEL INSULATION

8

B03455-01

ELECTRICAL KIT, BVSO INT.

9

F06F015

WASHER, ZINC 1 7/16"

10

Z99F061

OBSERVATION PORT

11

R02R009

HIGH LIMIT 175-36T,  7"

12

B03453

ELECTRICAL KIT, TT

13

B03454

ELECTRICAL KIT, BURNER

14

B03831

WIRE CHANNEL (BVSO/SWITCH)

15

B03819-01

BAFFLE

One baffle included

16

B03675

SMOKE OUTLET GASKET

17

B03842

RADIATOR BAFFLE

Item # 16 included

18

F07O001

FLANGE NUT, HEXAGONAL 3/8-16NC BRASS

19

F07F011

HEX NUT 3/8-16NC ZINC  

20

B01684

COVER, ELECTRICAL BOX

21

Z99F050

HANDLE , RECESSED BLACK

22

B03858-01

BLOWER DOOR ASSEMBLY

Door and labels included

23

B03854-02

REPLACEMENT BLOWER ASSEMBLY

Blower, motor  included

24

Z06G001

BLOCKED VENT SHUT-OFF BVSO-225

25

B03118-01

ELECTRICAL KIT, BVSO EXT.

26

L04I005

STRAIN RELIEF BUSHING

27

L04J001

CABLE CLAMP, 9/16" WHITE

28

B03640

WIRE CHANNEL, INT.

29

B03829

BLOWER DIVIDER

30

B03838

BLOWER SLIDE

One blower slide included

31

B03835-02

LATERAL BAFFLE

32

B03867-01

FILTER RACK KIT

33

B03828

FLOOR

34

B03855-02

SIDE PANEL ASSEMBLY (LEFT)

Panel, insulation and baffle included

35

B03857

REAR PANEL ASSEMBLY

Panel, insulation and baffles included

36

B03864

REAR PANEL INSULATION

37

B03836

REAR BAFFLE

38

B01682

SUPPORT, ELECTRONICS BOX

39

L01F009

TRANSFORMER, 120-24Volt, 40VA

40

B01683

ELECTRICAL BOX

41

R99G003

ELECTRONIC BOARD 1168

42

B03141

INDUCTOR

43

B03669

ELECTRICAL KIT, BOARD

44

B03242

ELECTRONIC KIT, BLOWER

45

B03243

ELECTRICAL KIT, BLOWER

46

B03720-07

BLOWER 120-10T DD 0,50PP

Housing, wheel and label included

47

B03813-07

MOTOR 1 HP ECM 2.3

48

B01889

MOTOR SUPPORT ASSEMBLY                        

Legs, band & hardware included

49

R02R007

HIGH LIMIT 120-20F, 1.75''

50

B03837

BLOWER SLIDE

One blower slide included

DOWNFLOW BASE

B03464-03

HORIZONTAL FLOW BASE

B00488-01

VENT TERMINAL KIT 5''

For sealed combustion

5" INSULATED FLEX VENT 8ft

For sealed combustion

5" INSULATED FLEX VENT 20ft

For sealed combustion

BECKETT NX BURNER (0.75-60B NOZZLE)

RIELLO 40-F5 BURNER (0.75-70A NOZZLE)

RIELLO 40-BF5 BURNER (0.75-70A NOZZLE)

For sealed combustion        

B50112A

ACCESSORIES

DFB-104

KLASB1001DET

HFB-101

KLASB0701DET

VTK-3

KLAVT0201DET

IFV-5-8

KLAFV0301DET

IFV-5-20

KLAFV0401DET

N01F056

KLABR0601RLO

N01J053

KLABR0301BEC

N01F053

KLABR0501RLO

 

Summary of Contents for AMP154SD

Page 1: ...erbrooke Québec Canada J1L 1V8 www dettson ca Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWNER PLEASE KEEP THIS MANUAL NEAR THE FURNACE FOR FUTURE REFERENCE US C DNS 1225A ...

Page 2: ...s of ventilation air openings in a closet door 4 Figure 2 Upflow Installation 4 Figure 3 Downflow Installation 5 Figure 4 Horizontal Installation 5 Figure 5 Thermostat wiring heating and air conditioning with 4 speed motor 5 Figure 6 Thermostat wiring heating and air conditioning with ECM variable speed motor 6 Figure 7 Thermostat wiring heating and air conditioning heat pump with ECM variable spe...

Page 3: ...nformation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform to local codes or in the absence of same to codes of the country having jurisdiction The information contained in this manual is intended for use by a qualified technician familiar with safety proced...

Page 4: ... designed for outdoor installation It must be installed in such a manner as to protect its electrical components from water Outdoor installation will lead to a hazardous electrical condition and to premature failure of the equipment The minimum clearances from combustible material for each of the positions are specified in Table 4 If the furnace is installed in a basement or on a dirt floor in a c...

Page 5: ...ground to minimize the risk of bodily harm if ever an electrical problem develops A green ground screw is supplied with the control box for that purpose The appliance must be installed in accordance with the current ANSI NFPA 70 National Electrical Code CSA C22 1 Canadian Electrical Code Part 1 and or local codes The control system depends on the correct polarity of the power supply Connect HOT wi...

Page 6: ...own in table 1 and based on a pump pressure of 100 psi Always select nozzle sizes by working back from the desired flow rate at operating pressure and not the nozzle marking 2 5 2 Air and Turbulator Settings Before starting the burner for the first time adjust the air and turbulator settings to those listed in this manual Once the burner becomes operational final adjustments will be required Refer...

Page 7: ...ove the three pole plug from the BVSO outlet on the furnace 3 The burner must shut off immediately while the blower continues to run to the end of the cool down cycle If the test is not in line with the above call a QUALIFIED SERVICE TECHNICIAN 2 8 COMBUSTION AIR SUPPLY AND VENTILATION WARNING Poisonous carbon monoxide gas hazard Comply with NFPA 31 U S and CSA B139 Canada standards for the instal...

Page 8: ...at only outside air be used for combustion a Commercial buildings b Buildings with indoor pools c Furnaces installed near chemical storage areas The installation must carefully be verified to ensure that the combustion air comes from outside 2 10 1 Air filter A properly sized air filter must be installed on the return air side of the unit Refer to the Technical Specifications table 6 for the corre...

Page 9: ...fier on the HUM terminal It supplies 120 VAC electric power when the burner is in operation A 24 VAC signal can also be supplied from the W and C terminals on the blower electronic board to activate a switching relay Also refer to the instructions supplied with the accessory 2 13 2 Electronic Air Cleaner EAC The EAC terminal on the electronic board supplies 120 VAC when the blower is operating in ...

Page 10: ...he oil piping and pump Slowly close and tighten the bleed screw Once closed the flame will light up 3 3 2 Pressure adjustment The oil pressure must be adjusted according to the Technical Specifications of this manual An adjustment screw and a connection for a pressure gauge are located on the oil pump for that purpose Also refer to the burner instruction manual 3 3 3 Combustion Check IMPORTANT The...

Page 11: ...iant heat from the heat exchanger 0 3 m 12 from the plenum of the main take off is usually sufficient 4 The temperature rise is calculated by subtracting the return air temperature from the supply air temperature 5 If the temperature rise is lower or exceeds the temperature specified in Table 6 change to the next lower or higher blower speed tap until the temperature rise falls to the target If th...

Page 12: ...t exchanger and combustion chamber should be inspected to determine if replacement is required 8 After the cleaning replace the heat exchanger baffles flue collar plate and oil burner 9 Readjust the burner for proper operation 4 2 CLEANING THE BLOCKED VENT SHUT OFF DEVICE BVSO For continuous safe operation the Blocked Vent Shut off device BVSO must be inspected and maintained annually by a qualifi...

Page 13: ...rvice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Ambient temperature F Chimney draft W C Overfire draft W C Test performed by ...

Page 14: ...A 0 90 70A Minimum and Maximum pump pressure PSIG 145 150 145 150 Combustion air adjustment turbulator damper 1 0 3 75 3 0 4 25 1 0 3 75 3 0 4 25 AFUE From CSA B212 standard and Canadian regulation 86 4 85 7 86 4 85 7 AFUE From ASHRAE 103 standard and US regulation 86 1 85 0 86 1 85 0 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer ...

Page 15: ...n Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 68 13 45 sec 19 60 sec 38 3 min B 1 ON 2 OFF 0 80 13 45 sec 19 30 sec 38 3 min C 1 OFF 2 ON All 13 45 sec 100 0 sec 100 2 min D 1 ON 2 ON All 13 90 sec 100 0 sec 100 2 min No adjustment required A C size PreRun On Delay CFM Level Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time All NO DELAY NO DELAY 100 90 sec OIL HEATIN...

Page 16: ...F FURNACE 1 5 08 cm 2 2 54 cm 1 5 08 cm 2 BOTTOM FURNACE 2 Ø 2 54 cm 1 3 5 08 cm 2 4 BACK FURNACE OPPOSITE SIDE OF THE BURNER 1 7 62 cm 3 7 62 cm 3 7 62 cm 3 PLENUM OR HORIZONTAL WARM AIR DUCT WITHIN 6 ft OF FURNACE 2 5 08 cm 2 7 62 cm 3 5 08 cm 2 FURNACE 2 N A 5 08 cm 2 N A FLUE PIPE AROUND FLUE PIPE 22 86 cm 9 22 86 cm 9 22 86 cm 9 FRONT FURNACE BURNER SIDE 1 45 72 cm 18 45 72 cm 18 45 72 cm 18 ...

Page 17: ...17 Figure 9 Furnace Dimensions ...

Page 18: ...18 Figure 10 Wiring diagram 4 speed motor PSC ...

Page 19: ...19 Figure 11 Wiring diagram variable speed motor ECM ...

Page 20: ...20 Figure 12 Parts list with 4 speed motor PSC B500111A ...

Page 21: ...640 WIRE CHANNEL INT 30 B03829 BLOWER DIVIDER 31 B03838 BLOWER SLIDE One blower slide included 32 B03835 02 LATERAL BAFFLE 33 B03867 01 FILTER RACK KIT 34 B03828 FLOOR 35 B03855 02 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 36 B03857 REAR PANEL ASSEMBLY Panel insulation and baffles included 37 B03864 REAR PANEL INSULATION 38 B03836 REAR BAFFLE 39 B01682 SUPPORT ELECTRONICS BOX 4...

Page 22: ...22 Figure 13 Parts list with variable speed motor ECM B50112A ...

Page 23: ...CHANNEL INT 29 B03829 BLOWER DIVIDER 30 B03838 BLOWER SLIDE One blower slide included 31 B03835 02 LATERAL BAFFLE 32 B03867 01 FILTER RACK KIT 33 B03828 FLOOR 34 B03855 02 SIDE PANEL ASSEMBLY LEFT Panel insulation and baffle included 35 B03857 REAR PANEL ASSEMBLY Panel insulation and baffles included 36 B03864 REAR PANEL INSULATION 37 B03836 REAR BAFFLE 38 B01682 SUPPORT ELECTRONICS BOX 39 L01F009...

Reviews: