2

 

 

 

TABLE OF CONTENTS 

 

1 SAFETY 

REGULATIONS ..................................... 3 

1.1 

SAFETY LABELING AND WARNING SIGNS ...... 3 

1.2 IMPORTANT 

INFORMATION............................... 3 

1.3 DETECTION SYSTEMS ....................................... 3 
1.4 DANGER 

OF FREEZING ..................................... 3 

2 INSTALLATION .................................................... 4 
2.1 POSITIONING 

THE FURNACE............................ 4 

2.1.1 Installation 

in an enclosure.................................... 4 

2.2 ELECTRICAL SYSTEM ........................................ 4 
2.3 INSTALLATION 

OF THE THERMOSTAT ............ 4 

2.4 INSTALLATION 

OF THE BURNER ...................... 5 

2.4.1 Nozzles ................................................................. 5 
2.4.2 

Air and Turbulator Settings ................................... 5 

2.4.3 

Post purge delay adjustment................................. 5 

2.5 VENTING.............................................................. 5 
2.5.1 Masonry chimney.................................................. 5 
2.5.2 Factory 

Built Chimneys ......................................... 5 

2.5.3 Draft 

Regulator...................................................... 5 

2.5.4 Side-wall 

venting ................................................... 6 

2.6 

BLOCKED VENT SHUT-OFF DEVICE (BVSO) 
FOR CHIMNEY VENTING.................................... 6 

2.6.1 BVSO 

Performance Test ...................................... 6 

2.7 

COMBUSTION AIR SUPPLY AND VENTILATION

.............................................................................. 6 

2.7.1 Contaminated 

Combustion Air .............................. 6 

2.7.2 

Burner with Outdoor Combustion Air Kit ............... 6 

2.8 OIL 

TANK ............................................................. 6 

2.9 DUCTING ............................................................. 7 
2.9.1 Air 

filter.................................................................. 7 

2.10 

SUPPLY AIR ADJUSTMENT (4 SPEED MOTOR)7 

2.10.1  Supply air adjustment (ECM variable speed 

motors).................................................................. 8 

2.11 INSTALLATION 

OF ACCESSORIES.................... 8 

2.11.1 Humidifier (HUM) .................................................. 8 
2.11.2 Electronic 

air Cleaner (EAC) ................................. 8 

2.11.3 Air 

Conditioner 

(or Heat Pump)............................. 8 

2.11.4  Emergency Heating Mode – Variable Speed Motor 

(ECM) ................................................................... 8 

3 OPERATION......................................................... 9 
3.1 START-UP............................................................ 9 
3.2 

OPERATING SEQUENCE OIL HEATING MODE 9 

3.3 

CHECKS AND ADJUSTMENTS ........................... 9 

3.3.1 Purging 

the oil line ................................................ 9 

3.3.2 Pressure adjustment ............................................. 9 
3.3.3 Combustion Check................................................ 9 
3.3.4 Draft 

Regulator adjustment ................................... 9 

3.3.5 Overfire 

pressure test ......................................... 10 

3.3.6 Vent 

Temperature Test ....................................... 10 

3.3.7 

Supply air Temperature Rise Test ...................... 10 

3.3.8 Limit 

Control Check............................................. 10 

3.3.9 Restart 

after burner failure .................................. 10 

4 MAINTENANCE.................................................. 10 
4.1 

CLEANING THE HEAT EXCHANGER ............... 10 

4.2 

CLEANING THE BLOCKED VENT SHUT-OFF 
DEVICE (BVSO) ................................................. 11 

4.3 

CLEANING OF THE BURNER HEAD ................ 11 

4.4 REPLACING 

THE NOZZLE................................ 11 

4.5 REPLACING 

THE OIL FILTER........................... 11 

4.6 REPLACING 

THE AIR FILTER........................... 11 

5 FURNACE 

INFORMATION ................................ 12 

 

INDEX OF TABLES 

 

Table 1: 

Blower speed adjustments (heating mode, 4 
speed motor)....................................................7 

Table 2: 

Blower speed adjustments (A/C mode, 4 speed 
motor) ..............................................................7 

Table 3: 

Heating Mode ..................................................8 

Table 4: 

Air Conditioning Mode......................................8 

Table 5: 

CFM adjustment - All Modes............................8 

Table 6: 

Delay adjustments - Heating Mode ..................8 

Table 7: 

Technical Specifications ................................13 

Table 8: 

Airflow Data, Models with 1.0 HP variable 
speed (ECM) motors......................................14 

Table 9: 

Airflow Data, Models with 1.0 HP 4 speed 
motors............................................................15 

Table 10:  Minimum clearances from combustible material

 15 

Table 11:  Parts List - With 4 Speed motor PSC.............20 
Table 12:  Parts List - With variable speed motor ECM ..22 
 

INDEX OF FIGURES

 

 
Figure 1: 

Location and dimensions of ventilation air 
openings in a closet door ..............................4 

Figure 2: 

Heating & Air Conditioning - With 4 Speed 
Motor.............................................................4 

Figure 3: 

Thermostat Wiring- Heating & Air 
Conditioning - With ECM Variable Speed 
Motor.............................................................5 

Figure 4: 

Thermostat Wiring-Heating &Air 
Conditioning/HeatPump - With ECM Variable 
Speed Motor .................................................5 

Figure 5: 

Blower "OFF" delay - Board #ST9103A ........7 

Figure 6: 

Blower start / stop delays - Board #1158.......7 

Figure 7: 

Furnace Dimensions ...................................16 

Figure 8: 

Wiring Diagram - 4 Speed Motor (PSC) ......17 

Figure 9: 

Wiring Diagram - Variable Speed Motor 
(ECM)..........................................................18 

Figure 10: 

Parts List - With 4 Speed motor PSC..........19 

Figure 11: 

Parts List - With variable speed motor ECM21 

 

Summary of Contents for AMT154SDMA

Page 1: ...ke Qu bec www dettson ca Attention Do not tamper with the unit or its controls Call a qualified service technician INSTALLER SERVICE TECHNICIAN USE THE INFORMATION IN THIS MANUAL FOR THE INSTALLATION...

Page 2: ...ply air Temperature Rise Test 10 3 3 8 Limit Control Check 10 3 3 9 Restart after burner failure 10 4 MAINTENANCE 10 4 1 CLEANING THE HEAT EXCHANGER 10 4 2 CLEANING THE BLOCKED VENT SHUT OFF DEVICE BV...

Page 3: ...formation such as the model and serial numbers of the furnace WARNING Installations and repairs performed by unqualified persons can result in hazards to them and to others Installations must conform...

Page 4: ...re the ambient and return air temperatures are above 15 C 60 F In addition the furnace should be installed as closely as possible to the vent so that the connections are direct and kept to a minimum T...

Page 5: ...ired for Riello burners Refer to the burner control instruction manual and markings for proper adjustment of the post purge delay 2 5 VENTING WARNING Poisonous carbon monoxide gas hazard Never install...

Page 6: ...equate supply of combustion air It is common practice to assume that older homes have sufficient infiltration to accommodate the combustion air requirement for the furnace However home improvements su...

Page 7: ...ated the return air must be sealed and also be directed to the space other than where the furnace is located 2 9 1 Air filter A properly sized air filter must be installed on the return air side of th...

Page 8: ...heating or air conditioning mode This signal can be used to activate an electronic air cleaner that is not equipped with an air flow switch If the cleaner is equipped with an air flow switch the S te...

Page 9: ...of the oil piping and pump Slowly close and tighten the bleed screw Once closed the flame will light up 3 3 2 Pressure adjustment The oil pressure must be adjusted according to the Technical Specifica...

Page 10: ...burner should restart after a few minutes The time required for the restart also depends on the adjustment of the blower OFF delay 3 3 9 Restart after burner failure 1 Set the thermostat lower than r...

Page 11: ...uction inside the heat transfer tube 7 Re mount lock and fasten the control box with the 2 screws removed in step 4 8 Re attach the assembly cover with the screws removed in step 2 9 Re establish powe...

Page 12: ...vice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F Am...

Page 13: ...n 87 5 86 2 87 5 86 2 Volts Hertz Phase Rated current Amps Minimum ampacity for wire sizing Amps Max fuse size Amps Control transformer VA External control power available Heating VA Cooling VA Heatin...

Page 14: ...Time ShortRun On Delay CFM Level Time Off Delay CFM Level Time A 1 OFF 2 OFF 0 90 13 45 sec 44 30 sec 38 3 min B 1 ON 2 OFF 1 10 13 30 sec 44 30 sec 38 3 min C 1 OFF 2 ON 1 10 13 30 sec 50 30 sec 38...

Page 15: ...WITH AIR FILTER Table 10 Minimum clearances from combustible material LOCATION APPLICATION CLEARANCES combustible materials RECOMMANDED ACCESS FOR SERVICE FURNACE 2 54 cm 1 0 6 m 24 SUPPLY PLENUM WIT...

Page 16: ...16 Figure 7 Furnace Dimensions...

Page 17: ...17 Figure 8 Wiring Diagram 4 Speed Motor PSC...

Page 18: ...18 Figure 9 Wiring Diagram Variable Speed Motor ECM...

Page 19: ...19 Figure 10 Parts List With 4 Speed motor PSC B50095B...

Page 20: ...TERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 GASKET SMOKE OUTLET 37 B03765 CLEAN OUT ASSEMBLY Item 36 included 38...

Page 21: ...21 Figure 11 Parts List With variable speed motor ECM B50096C...

Page 22: ...ELECTRICAL BOX COVER Panel only 32 B03118 01 ELECTRICAL KIT BVSO EXTERIOR 33 F06F015 ZINC WASHER 1 7 16 34 Z99F061 SIGHT GLASS FOR HEAT EXCHANGER 35 Z06G001 BLOCKED VENT SHUT OFF BVSO 225 36 B03675 G...