1.0  SAFETY REGULATIONS

 

 

FOR YOUR SAFETY 

 

DO  NOT  STORE  OR  USE  GASOLINE  OR  OTHER 
FLAMMABLE  VAPORS  AND  LIQUIDS  IN  THE  VICINITY 
OF THIS OR ANY OTHER APPLIANCE. 
 
DO  NOT  ATTEMPT  TO  START  THE  BURNER  WHEN 
EXCESS 

OIL 

HAS 

ACCUMULATED, 

WHEN 

THE 

FURNACE  IS  FULL  OF  VAPOUR  OR  WHEN  THE 
COMBUSTION CHAMBER IS VERY HOT. 

 
 
1.1 

DANGER, WARNING AND CAUTION 

 
The  words  DANGER,  WARNING  and  CAUTION  are  used  to 
identify  the  levels  of  seriousness  of  certain  hazards.  It  is 
important  that  you  understand  their  meaning.  You  will  notice 
these words in the manual as follows: 

 

DANGER 

 

Immediate  hazards  which  WILL  result  in  death  or 
serious bodily and/or material damage. 

 

 

WARNING 

 

Hazards  or  unsafe  practices  which  CAN  result  in  death 

or serious bodily and /or material damage. 

 

 

CAUTION 

 

Hazards  or  unsafe  practices  which  CAN  result  in  minor 

bodily and /or material damage. 

 

 
 
1.2 

IMPORTANT INFORMATION 

 

WARNING 

 

For  use  with  grade  2  fuel  oil  maximum.  Do  NOT  use 

gasoline, crankcase oil or any oil containing gasoline. 

 

 

WARNING 

 

Never burn garbage or paper in the heating system and 

never leave rags or paper around the unit. 

 

 

CAUTION 

 

These  instructions  are  intended  for  the  sole  use  of 

qualified  personnel  trained  in  installing  this  type  of 
furnace.  Installation  of  this  furnace  by  an  unqualified 
person  can  lead  to  hazardous  conditions,  resulting  in 
bodily harm and/or equipment damage. 

 

 
 

IMPORTANT:  All  local  and  national  code  requirements 
governing  the  installation  of  oil  burning  equipment,  wiring 
and  flue  connections  must  be  followed  some  of  the  codes 
that may be applicable are : 
 
CSA B139 

Installation code for oil burning 

 

equipment 

ANSI/NFPA 31 

Installation of oil burning equipment 

ANSI/NFPA 90B 

Warm air heating and air conditioning 

 

systems 

ANSI/NFPA 211 

Chimneys, fireplaces, vents and solid 

 

fuel burning appliances 

ANSI/NFPA 70 

National electrical code 

CSA C22.1  

Canadian electrical code 

 
Only  the  latest  issues  of  the  above  codes  should  be  used, 
and are available from either: 

 

The National Fire Protection Agency 

 

Batterymarch Park 

 

Qunicy, MA 02269 

or 
  

The Canadian Standards Association 

 

178 Rexdale Blvd. 

 

Rexdale, Ontario M9W 1R3 

 

CAUTION 

 

ENVIRONMENTAL HAZARD 

 

Failure 

to 

follow 

this 

caution 

may 

result 

in 

environmental pollution. 

 

Remove  and  recycle  all  components  or  materials  (i.e. 

oil,  electrical  and  electronic  components,  insulation, 
etc.) before unit final disposal. 

 

 
 
 

2.0  INSTALLATION 

 
2.1 

GENERAL 

 
This  furnace  is  a  Low-Boy  and  operates  only  in  an  upflow 
configuration. 
 
The appliance is shipped as a packaged unit, complete with 
burner and controls.  It requires a line voltage connection to 
the  control  box  (240/120  VAC,  60Hz  with  3  wires  plus 
ground),  thermostat  hook-up  as  shown  on  the  wiring 
diagram,  oil  line  connection(s),  proper  ductwork,  and 
connection to a properly sized vent. 
 
The  air  handling  capacity  of  this  furnace  is  designed  for 
cooling air flow.  Refer to Table 3 for the expected airflow at 
various external duct static pressures. 

 

IMPORTANT:  If  sidewall  venting  is  not  used  at  the  time  of 
the  installation,  place  a  jumper  between  terminals  #  2  and    
# 3. 

 
 
 
 

Summary of Contents for LOW-BOY AME15-79

Page 1: ...79 AME20 90 AME25 100 DNS 0671 R v A C Fabriqu par Industries Dettson Inc 3400 boulevard Industriel Sherbrooke Qu bec Canada J1L 1V8 www dettson ca INSTALLATEUR TECHNICIEN UTILISER LES RENSEIGNEMENTS...

Page 2: ...igne de mazout 8 3 2 3 V rification de la combustion 9 3 2 4 V rification de l ajustement du ventilateur 9 3 2 5 V rification des limiteurs de temp rature 10 3 2 6 Ajustement du limiteur 10 3 2 7 V ri...

Page 3: ...ation de cet appareil par une personne non qualifi e peut endommager l quipement et ou conduire des conditions hasardeuses susceptibles d entra ner des dommages corporels IMPORTANT Toutes les exigence...

Page 4: ...contr le des odeurs D autre part en plus de l air de combustion une quantit suffisante d air doit tre fournie pour la ventilation incluant l air n cessaire pour le confort et des conditions de travai...

Page 5: ...11 Chemin es foyers vents et appareils de chauffage au combustible solide et ou CSA B139 Code d installation Cet appareil de chauffage central est homologu pour tre utilis avec un vent de type L temp...

Page 6: ...ce de votre unit et l amp rage nominal afin de choisir un disjoncteur et une protection de calibre suffisant L unit requiert une alimentation 240 120 Volts AC 60 Hz 3 fils plus mise la terre Installer...

Page 7: ...S il y a panne de ventilateur ou obstruction excessive dans le conduit d air chaud le g n rateur est muni d un contr le de haute limite qui emp che le br leur de surchauffer et d endommager le g n rat...

Page 8: ...peut tre allum ou non Voyant AUTO RELEVE et voyant ELECTRICITE Lorsque le voyant AUTO RELEVE est allum en m me temps que le voyant ELECTRICITE ceci signifie qu il y a un probl me sur le mode MAZOUT V...

Page 9: ...u un quivalent 3 Afin d effectuer la v rification de la combustion suivre les tapes suivantes a Percer un orifice d analyse des gaz de diam tre minimum appropri e environ 9 32 dans le tuyau de raccord...

Page 10: ...ider le bon fonctionnement de la prise BVSO sur l unit de chauffage seulement 1 Faire fonctionner le br leur 2 D brancher la prise 3 p les identifi e BVSO sur l unit 3 Le br leur doit s arr ter imm di...

Page 11: ...t pouvez inspecter visuellement ou l aide d un voltm tre chacun des l ments Si vous avez changer un l ment suivez la proc dure suivante 1 D branchez les 2 fils lectriques de l l ment retirer 2 D visse...

Page 12: ...t adresse du technicien de service R SULTAT DU TEST DE MISE EN MARCHE Gicleur Pression lb po 2 Ajustements du br leur Bande principale Bande fine Position de la t te CO2 Indice de fum e Bacharach Temp...

Page 13: ...van 0 65 80W 0 75 80W 0 85 80W Ajustement air de combustion bande obturateur 0 7 1 4 0 9 SYST ME LECTRIQUE Volts Hertz Phase 240 120 60 1 Contr le du transformateur 40 VA DONN ES TECHNIQUES DU VENTILA...

Page 14: ...MENT APPLICATION D GAGEMENT MINIMUM FOURNAISE 15 cm 6 PLENUM D ALIMENTATION 5 cm 2 AUTRE C T FOURNAISE 60 cm 24 ARRI RE FOURNAISE 60 cm 24 DESSUS FOURNAISE OU PLENUM 5 cm 2 DESSOUS FOURNAISE PLANCHER...

Page 15: ...15 Figure 3 Emplacement des composantes principales Figure 4 Localisation du tiroir d l ments DNS 0202 R v C DNS 0209 R v A...

Page 16: ...16 Figure 5 D montage du tiroir d l ment...

Page 17: ...17 Figure 6 Diagramme lectrique...

Page 18: ...18 Figure 7 Liste de pi ces B50047 Rev A...

Page 19: ...PLAQUE DE RETENUE 30 B02301 GARNITURE SORTIE DES GAZ 31 B02311 ASS SORTIE DES GAZ 32 B02312 ASS PIEGE A SON COMPLET 33 F07O001 ECROU HEXAGONAL A BRIDE 3 8 16NC LAITON 34 Z99F050 POIGNE ENCASTRE NOIR 3...

Page 20: ...SUS 70 B01154 PORTE D ACCES 71 B01095 ASS D LEMENTS 72 A00207 11 FIL ELECTRIQUE ROUGE 73 A00201 19 FIL ELECTRIQUE NOIR 74 L04J002 BRIDE DE CABLE 7 8 NOIR 75 B01123 03 TIROIR D L MENT 76 B01123 01 TIRO...

Page 21: ...Printed on 100 recycled paper DNS 0671 Rev A C Manufactured by Industries Dettson inc 3400 Industrial Boulevard Sherbrooke Quebec Canada J1L 1V8 www dettson ca INSTALLER SERVICE TECHNICIAN USE THE INF...

Page 22: ...OIL MODE 7 3 2 1 Operational checklist 7 3 2 2 Purging the oil line 8 3 2 3 Combustion check 8 3 2 4 Fan adjustment check 8 3 2 5 Limit Control check 9 3 2 6 Limit Control adjustment 9 3 2 7 BVSO perf...

Page 23: ...e installation of oil burning equipment wiring and flue connections must be followed some of the codes that may be applicable are CSA B139 Installation code for oil burning equipment ANSI NFPA 31 Inst...

Page 24: ...equate to provide air for combustion ventilation and dilution of flue gases This determination must be made on an individual installation basis and must take into consideration the overall volume of t...

Page 25: ...himney the chimney must be of sufficient area to accommodate the total flue products of all appliances vented into the chimney The following requirements are provided for a safe venting system a Ensur...

Page 26: ...y harm An internal filter rack located in the blower compartment is provided as standard equipment with this furnace A sufficient clearance should be provided for air filter access Refer to Table 2 fo...

Page 27: ...rner problem If the furnace is in the oil mode with both the AUTO RELIEF and OIL lights on there is a problem with the electrical system Twelve hours following detection of AUTO RELIEF the furnace wil...

Page 28: ...rformance from the oil burner the following set up procedures must be followed by referring to the Technical Specifications Table 2 in this manual 1 A test kit to measure the smoke flue draft and over...

Page 29: ...unction of the furnace and cause premature wear of the heat exchanger CAUTION Modification of the factory set limits will void the warranty 3 2 7 BVSO performance test The purpose of the following tes...

Page 30: ...lace an element follow the steps below 1 Disconnect the 2 wires attached to the element 2 Remove the metal screws that hold the frame on the drawer bottom of the drawer 3 Remove the frame by unscrewin...

Page 31: ...rvice telephone Day Night Dealer name and address START UP RESULTS Nozzle Pressure lb po 2 Burner adjustments Primary air Fine air Drawer Assembly CO2 Smoke scale Bacharach Gross stack temperature F A...

Page 32: ...le 100 PSIG pump pressure Delavan 0 65 80W 0 75 80W 0 85 80W Combustion air adjustment shutter band 0 7 1 4 0 9 ELECTRICAL SYSTEM Volts Hertz Phase 240 120 60 1 Control transformer 40 VA BLOWER DATA B...

Page 33: ...E A R A N C E S F U RN A CE 15 c m 6 S U P P LY P L E N U M 5 c m 2 O T HE R S I DE F U RN A CE 60 c m 24 B A C K F U RN A CE 60 c m 24 T O P F U RN A CE O R P LE NU M 5 c m 2 B O T T O M F U RN A CE...

Page 34: ...14 Figure 3 Location of main componants Figure 4 Location of element drawer DNS 0202 R v C DNS 0209 R v A...

Page 35: ...15 Figure 5 Element drawer removal...

Page 36: ...16 Figure 6 Electrical Diagram...

Page 37: ...17 Figure 7 Parts List B50047 Rev A...

Page 38: ...ation 29 B02305 Holding plate 30 B02301 Breech plate gasket 31 B02311 Breech plate 32 B02312 Sound trap ass y 33 F07O001 Hex nut brass 34 Z99F050 Recessed handle black 35 Z04F010 Paper filter 16 x 20...

Page 39: ...70 B01154 Acces door 71 B01095 Electrical element ass y 72 A00207 11 Red w ire 73 A00201 19 Black w ire 74 L04J002 Cable clamp 75 B01123 03 Element draw er 76 B01123 01 Element draw er 77 B01123 02 El...

Page 40: ...20...

Reviews: