b) Ask someone to frequently check the house during

the cold weather season to make sure that there is
sufficient heat to prevent the pipes from freezing.
Tell this person to call an emergency number if re-
quired.

2

INSTALLATION

This furnace is a true multi-position unit, in that it will
function in an upflow, downflow or horizontal configura-
tion to the left or the right. Only a few modifications are
required during installation to change from one position
to another. The unit is shipped in the upflow configura-
tion and instructions as to how to change to the other
positions are included in this manual.
The unit requires a 120/240 - 208 VAC power supply to
the control panel, thermostat hook-up as shown on the
wiring diagram.

2.1

POSITIONING THE FURNACE

WARNING

FIRE AND EXPLOSION HAZARD
The furnace must be installed in a level position,
never where it will slope toward the front.
Do not store or use gasoline or any other
flammable substances near the furnace.
Non-observance of these instructions will poten-
tially result in death, bodily injury and/or property
damage.

WARNING

This furnace is not watertight and is not designed
for outdoor installation.

It must be installed in

such a manner as to protect its electrical compo-
nents from water. Outdoor installation will lead to
a hazardous electrical condition and to premature
failure of the equipment.

If the furnace is installed in a basement or on a dirt

floor, in a crawl space for example, it is recommended to
install the unit on a cement base 2.5 cm to 5.0 cm (1” to
2”) thick.
In addition, the heater should also be located close to the
center of the air distribution system.

2.2

CLEARANCES TO
COMBUSTIBLE MATERIAL

2.2.1

Heating unit

The furnace is approved for zero clearance to com-
bustible material regardless of the heating capacity.

2.2.2

Supply air ducts

Ducts can be installed with a zero clearance to com-
bustible material.

2.3

CONFIGURATIONS

This furnace requires suitable ductwork.

2.3.1

Upflow installation

The return duct may be installed to the back, to the bot-
tom, on the left side or on the right side of the unit. The
supply duct shall be installed on the top of the unit. Care
should be taken not to damage the wires inside, while
cutting the opening. Instal the filter rack that is supplied
with the unit. It is also recommended to install the blower
door before handling or moving the unit. Refer to Figure
1 for additional details.

Figure 1: Upflow Configuration

2.3.2

Downflow installation

The return duct may be installed to the back, on the left
side, on the right side or under the unit. The supply duct
shall be installed on the top of the unit.
When the furnace is installed in the downflow position on
a combustible floor, the downflow base DFB-SUP can be
used. Refer to Figure 2 and the installation instructions
provided with the base.

Figure 2: Downflow Configuration

2.3.3

Horizontal installation

The return duct may be installed to the back, on the left
side, on the right side or under the unit. The supply duct
shall be installed on the top of the unit.
When the furnace is installed in the horizontal position,

3

Summary of Contents for SUPREME SUP A240V12 Series

Page 1: ...its controls Call a qualified service technician USE THE INFORMATION IN THIS MANUAL FOR THE IN STALLATION AND SERVICING OF THE FURNACE AND KEEP THE DOCUMENT NEAR THE UNIT FOR FUTURE REFERENCE HOMEOWN...

Page 2: ...mostat 9 3 3 6 Electric heating mode Communicating thermostat 9 3 3 7 Heat pump heating mode Modlating thermostat outdoor unit single stage 9 3 3 8 Heat pump heating mode Modulating thermostat outdoor...

Page 3: ...alified service technician immedi ately to assess the damage and to replace all criti cal parts that were in contact with water c Do not store gasoline or any other flammable sub stances such as paper...

Page 4: ...ample it is recommended to install the unit on a cement base 2 5 cm to 5 0 cm 1 to 2 thick In addition the heater should also be located close to the center of the air distribution system 2 2 CLEARANC...

Page 5: ...pted ground to minimize the risk of bodily harm A ground terminal is supplied with the control box for that purpose A connector is supplied on the ground terminal to ground an added accessory In the e...

Page 6: ...mode is comfort able and economical Generally speaking on a single stage thermostat a reading of the current must be taken with an ammeter as follows 1 Move the anticipator to its highest setting rend...

Page 7: ...d to operate prop erly with system components with which it is installed To successfully configure a system see information printed on circuit board label located next to select pins move the 6 select...

Page 8: ...t up cool down in conjunction with the airflow 3 0 0 No delay option Used for servicing unit or when a thermostat is utilized to perform delay func tions 4 ENH enhanced selection provides a 30 second...

Page 9: ...control will detect the humidistat contact opening on increasing humidity and reduce its airflow to approximately 80 of nominal cooling mode airflow This reduction will increase the system latent cap...

Page 10: ...o Y Y2 and R to O b Furnace delivers single stage cooling airflow 3 3 3 Cooling mode two stage First stage low cooling Thermostat closes cir cuits R to G R to O and R to Y1 Furnace delivers low stage...

Page 11: ...ir temperature from the supply air tempera ture If the temperature rise exceeds the temperature spec ified in Table 2 by 5 F 2 8 C move the AC HP CFM ADJUST black wire to high HI position If the exces...

Page 12: ...nt changes Dirty filters have an adverse ef fect on the performance of the central heating system 4 2 MOTOR LUBRICATION Do not lubricate the blower motor since it is permanently lubricated 5 FURNACE I...

Page 13: ...ected cooling delays Cooling 2 stages with Electric Heat Continous Fan G ON Fan ON at the selected continous fan CFM Fan switch ON OFF Fan OFF Thermostat calls for 1st stage Heat W1 ON Fan ON at 50 of...

Page 14: ...DH ON Compressor ON Fan ON after delays at 80 of the selected Cooling CFM OFF Compressor OFF Fan OFF after selected cooling delays Thermostat calls for 1st stage Heat Heat pump heating mode Y1 G ON Co...

Page 15: ...5 3 7 4 3 1 5 3 7 Electrical element 6 240V 208V Kw 4 3 1 5 3 7 Blower motor Consumption 240V 208V Amp Max 2 3 2 7 2 3 2 7 2 3 2 7 2 3 2 7 2 3 2 7 2 3 2 7 5 2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 5 2 6 0 Heati...

Page 16: ...sides the back and below KOE Identical on the 2 sides Identique sur les 2 cot s KOE A 35mm 44mm 1 3 8 1 3 4 B 29mm 7 8 A B Identique sur les 2 cot s au dos et en dessous DNS1455 rev C 927mm 36 1 2 559...

Page 17: ...s 24VAC input to Y1 only Y Y2 not powered CONTINUOUS FAN CFM1 CFM1 CFM1 AC HP SIZE A C size CONTINUOUS FAN CONTINUOUS FAN CONTINUOUS FAN Selection TONS YELLOW wire position YELLOW wire position YELLOW...

Page 18: ...to Y1 only Y Y2 not powered CONTINUOUS FAN 24 VAC R input on G only CFM1 CFM1 CFM1 AC HP SIZE A C size CONTINUOUS FAN CONTINUOUS FAN CONTINUOUS FAN Selection TONS YELLOW wire position YELLOW wire pos...

Page 19: ...ON OFF DELAY Adjustment ON Delay OFF Delay WHITE wire position Time CFM Time 0 90 0 sec 100 90 sec 30 90 30 sec 100 90 sec 0 0 0 sec 0 sec ENH 30 sec 70 150 sec DELAY PROFILE FOR ELECTRIC HEATING MODE...

Page 20: ...Figure 16 Electrical diagram SUPREME Advantage ECM ELECTRICAL DIAGRAM DIAGRAMME LECTRIQUE ADVANTAGE AVANTAGE ECM 19...

Page 21: ...rev E 31 12 15 16 17 11 6 8 9 18 19 20 21 22 13 14 7 10 REV DESCRIPTION A C DATE PAR A Nouveau dessin 21963 2015 03 24 F H B Changement disjoncteur CQC 22327 2015 05 19 F H C Ajoute support de filtre...

Page 22: ...upreme 15kw 21 B04284 Electrical sequencer kit Supreme 10kw 22 B04350 02 Top door 23 B04349 Bottom door assembly 24 B04357 01 Blower assembly Supreme 10 25kw 1 2hp ECM 25 B04357 02 Blower assembly Sup...

Reviews: