Page 5: ...lay 10 4 1 Dimensions and mounting 10 4 2 Terminal assignment 10 4 2 1 Option X79 42V holding level 10 4 3 LEDs 11 5 SPEEDY switching modes 12 5 1 Setting the switching modes 12 5 2 Switching mode 1 1...

Page 6: ...Deutschmann Automation GmbH Co KG 6 Instruction manual dynamical switching accelerator SPEEDY V 3 1 30 1 20...

Page 7: ...n unit specified on the cover sheet and in the header 1 1 1 Symbols Particularly important text sections can be seen from the adjacent picto gram You should always follow this information since otherw...

Page 8: ...c switching accelerator SPEEDY V 3 1 30 1 20 2 EMC Directives for products of Deutschmann Automation The installation of our products has to be carried out considering the relevant EMC directives as w...

Page 9: ...shorten the delay period SPEEDY offers the possibility to achieve an overexcitation of the magnetic field by an over voltage impulse of 100V adjustable from 1ms to 10ms Therefore the mechanical inert...

Page 10: ...drawing SPEEDY 4 2 Terminal assignment SPEEDY is connected via a 10 pin screw plug connector The following terminal assignment applies Terminal Function 1 GND reference for terminal 3 6 2 GND referen...

Page 11: ...r terminal 3 6 3 Input 4 24V max 10mA 4 Input 3 24V max 10mA 5 Input 2 24V max 10mA 6 Input 1 24V max 10mA 7 Output 2 max 1A 8 Output 1 max 1A 9 GND reference for terminal 7 8 and 10 10 10 30V max 3A...

Page 12: ...itched off 6 5 5ms Switched off 7 5 10ms Switched off 8 1 Active 9 2 Active A 3 Active B 4 Active C 5 1ms Active D 5 2ms Active E 5 5ms Active F 5 10ms Active Please note that every change of the inpu...

Page 13: ...itching modes 5 2 Switching mode 1 In switching mode 1 input 1 is switched to output 1 and input 2 is switched to output 2 The dura tion of the overexcitation pulse is set at the inputs 3 and 4 Pictur...

Page 14: ...there is no signal at input 3 input 1 and input 2 are inoperable The duration of the overexcitation pulses is set at input 4 Picture 3 Switching mode 2 Input 1 Input 2 Input 3 Output 1 Output 2 0 VDC...

Page 15: ...signal at input 1 is cancelled Output 1 is deactivated first followed by a pause after which not before output 2 is switched back on Input 2 determines the dura tion of the pause The duration of the...

Page 16: ...l is now cancelled at input 2 RESET 0 V DC output 1 is deactivated and output 2 is activated This circuit state remains stable even if input 2 receives a signal again 24 V DC Input 2 RESET has priorit...

Page 17: ...chapter 5 1 10ms Input 1 Input 2 Input 3 Input 4 Output 1 Output 2 0 VDC 0 VDC 0 VDC 0 VDC Unchanged Unchanged 24 VDC 0 VDC 0 VDC 0 VDC Unchanged Unchanged 0 VDC 24 VDC 0 VDC 0 VDC Unchanged Unchange...

Page 18: ...ol ding voltage e g 12V instead of 24V 6 1 Recovery times of SPEEDY The overexcitation voltage of 100 V is generated internally by SPEEDY and buffered in a capac itor The capacitor is partially discha...

Page 19: ...p to 2 5mm2 Display Optional LED status display of the inputs outputs and supply voltages Optional LED status display of the inputs outputs and supply voltages SPEEDY 100V 7 2 SPEEDY 50V SPEEDY 50V 1A...

Page 20: ...rarely more than 3 working days Technical Support hours are as follows Monday to Thursday from 8 am to midday and from 1 pm to 4 pm Friday from 8 am to midday CET Deutschmann Automation GmbH Co KG Car...

Page 21: ...or description undergo a standard test You have to bear the costs for that test even though no defect was found 8 2 Internet The current software WINLOC32 is available for download from our Internet h...