Operation modes of the Gateway
4
Operation modes of the Gateway
4.1 Configuration mode (config mode)
The configuration mode serves to configure the Gateway. The following adjustments are possible
in this mode.
•
Loading a Script
•
Updating the firmware (only CL-basis)
•
Configuring the Gateway (via WINGATE version V2.82 or higher)
The Gateway will be starting in this mode in case both switches S4 as well as S5 are set on posi-
tion "F" when switching on the Gateway. Right after switching on the Gateway in the configura-
tion mode it will be sending its starting message, that looks analog with the following message:
"RS-DN-CL[Cfg=256] (RS+Ext.Board) V6.6[42] (c)dA[40MHz] Switch=0x41FF
Script(C:11781/16128,V:13022/16384)="Universalscript Deutschmann EL" Author="G/S"
Version="V1.6.0" Date=30.09.2016 SN=47110001
Ext-Board: EL-IO-DICNET[193] V1.51 (c)dA 47110211
FE: IP=0.0.0.0 MAC=00-14-11-15-1A-53 Data-Flash=1MB“.
In the configuration mode the Gateway always operates with the settings 9600 Bauds, no Parity,
8 databits and 1 stopbit, the RS-State LED will always be flashing red, the "Error No/Select ID"
LEDs are of no account for the user. All software revisions contain the configuration mode.
4.1.1
Data structure on the Ethernet-Side in configuration mode
10/100 Base-T:
1. + 2. Byte Echo of the received Ethernet data
3. Byte Zero
4. Byte Echo of the received Ethernet data
5. Byte FF
6. - 8. Byte Version of the Ext. Card e.g. 13
Connection setting for 10/100 Base-T (RJ45 connector)
This connector has four channels (sockets) with the following transport protocols:
Channel
Transport
protocol
Config mode Test mode
data exchange mode
Channel 1
TCP server
(TCP/IP server)
port 23
default
Channel 2
Web server
Channel 3
FTP (Control)
Channel 4a FTP (Data)
After FTP connec-
tion UDP connec-
tion is erased
Channel 4b UDP
(UNIGATE
®
Scan)