21.4.15
Instruction manual UNIGATE
®
IC - Powerlink V. 2.3
27
Deutschmann Automation GmbH & Co. KG
Script and configuration
7
Script and configuration
7.1
Overview
The script stored in the UNIGATE
®
IC, as well as the configuration, can be replaced or updated
via the serial interface (application) in the configuration mode.
7.2
The configuration mode
If the pin „ConfigMode“ pulled to GND during the PowerUp or Reset, then the UNIGATE
®
IC
starts in the configuration mode. In this mode it is possible to communicate with the IC without
processing the regular software. It is also possible to change the UNIGATE
®
IC’s settings of the
standard software or to write a new script in the UNIGATE
®
IC. It shows its start in the configura-
tion mode by issuing a status message (it may take up to 1 minute), which might look as follows:
IC-PL-SC V0.31[30] (c)dA Script(16k)="Leer" Author="Deutschmann Automation GmbH"
Version="1.0" Date=21.08.2001 SN=47110001 IP=10.10.10.10 MAC=00-14-11-15-19-81
7.3
Update the script
•
The preferred option is to insert the UNIGATE
®
IC into the base board from Deutschmann
(Developer Board UNIGATE
®
IC-AB) and use the Deutschmann tools (software WINGATE with
„Write Script“ under „File“ or with the software ScriptProgramTool).
•
On request the procedures, how to overwrite the included script can be disclosed by
Deutschmann Automation in order to automatically replace the script in an application.
•
It is also possible to change the Script via FTP (see chapter 9.1 ’Script-update via FTP’).
Note:
After a change (download of a new configuration or a new Script) it takes
up to one minute until the IC has saved this change and will be ready for
operation.
7.4
Configuration of the UNIGATE
®
IC
UNIGATE
®
IC is delivered with an empty script.
The configuration of the UNIGATE
®
IC - Powerlink is restricted to the setting of the Ethernet-
address.
7.4.1
Ethernet
•
Protocol (UDP/IP or TCP/IP)
•
Baud rate: 10 and 100 MBaud autodetect
•
IP-address (Gateway)
•
Ethernet (MAC-address)
•
IP-destination host