User Manual DEV 1953
76
Copyright DEV Systemtechnik GmbH 2015-2017
Note:
The device has to be in Local Mode and in Individual switching mode to change
the group assignment of a switch module; otherwise the assignment matrix is
grayed out.
It is recommended to use consecutive group numbers (starting from "Group 1")
to keep the reference to the entries in the SNMP .switchGroupTable
(chapter 5.9.4.3.5).
It is suggested to configure groups for the installed switch (!) modules as
desired and to assign all empty slots and all slots populated with a passive
module or with a distribution amplifier module to the next vacant group
number.
A group is shown and can be selected within the structuring entry "
Groups
" on
the left side of the Control Tab (chapter 5.5.4) if it contains at least one
member.
5.5.7.3.4
Time Based Switching
Time Based Switching is a functionality to enable the time controlled switching of
the device.
The following prerequisites are to be considered:
Time Based Switching is to be configured via the Web Interface, only.
The device needs to obtain the present time from a timeserver, i.e. the
network setup of the device may have to be supplemented with the entry for a
valid timeserver, and the local timezone may have to be adjusted, please refer
to chapter 5.5.7.2.1.
The present device time is displayed in the top of the window left to the
button. Note that if there was no timeserver detected at power up, the device
sets the date and time to "01-Jan-2000 00:00".