User Manual DEV 1953
Copyright DEV Systemtechnik GmbH 2015-2017
135
6.1.4
Digital Interface Events
A digital interface module (please refer to chapter 3.2.26) is installed if the device is
equipped with Option 56 or with Option 57. The communication with the module
and the module temperature are monitored.
Error
Code
Description
Decimal
Hexadecimal
20736
0x5100
In/Output Module 1
31232
0x7A00
Overtemp Module 1
6.1.5
RF Level Monitoring Events
If the device is equipped with sensing switch modules, the RF level of each input
port is monitored (i.e. up to 32 ports) and an event is generated in case that the
RF level falls below the defined RF threshold level.
Error
Code
Description
Decimal
Hexadecimal
31744...31775
0x7C00...0x7C1F
RF Sense Port [i]
(i = {1…32})
6.1.6
Digital Signal Quality Events
If the device is equipped with digital signal modules, the digital signal quality of
each input port is monitored and an event is generated in case that the signal
quality becomes "Fail".
[i] is {1…2} for the input ports of the first digital signal switch module and is
{31…32} for the input ports of the sixteenth digital signal switch module.
If distribution amplifier modules for ASI/SDI signals are installed, [i] is {33} for the
input port of the first distribution amplifier module and is {48} for the input port of
the sixteenth distribution amplifier module.
Error
Code
Description
Decimal
Hexadecimal
32000...32047
0x7D00...0x7D2F
Signal Status Port [i]
(i = {1…48})
6.1.7
Other Events
For the sake of completeness, the other error codes that might be reported by the
device are listed here. If experiencing one of these events, please contact
DEV Systemtechnik for assistance.
Error
Code
Description
Decimal
Hexadecimal
02560
0x0A00
Internal
16384
0x4000
System Setup/Config