Customer Documentation DEV 5071
Copyright DEV Systemtechnik GmbH 2007-2017
15
the DEV 5071, then
Finally, check the settings of the installed power supply module via the Web
Interface. If there were changes on the default configuration of the power
supply modules (chapter 4.3.1) and if a defective module is replaced by an
exchange power supply module, the settings are transferred to the new
module. Nevertheless, it is recommended to check the settings of the new
power supply module directly after the exchange, to ensure, that the device
behaves in the same fashion as before the substitution.
4.2.4
Reboot of the Device and Restore of the Factory Default Settings
During power-up or during a reboot, the CPU module performs a health
check and scans the assemblies of the device e.g. to detect, whether a
module is installed in a slot or not. If there is a module installed, the settings
for this slot are transferred to the module.
Usually it is not possible to apply AC to all installed power supply modules at
power-up
in parallel
, or there are different latencies within the power supply
modules. Additionally, it is possible that there were applied changes on the
setup of the device, e.g. adding or swapping power supply modules.
Therefore, it is
highly recommended
to reboot the device after power-up or
after applying changes to the setup of the DEV 5071!
The reboot of the device can be performed in three different ways:
1. Reboot via the "Reset" push button of the CPU module; please refer to
chapter 3.2.2.
2. Reboot via the serial interface when terminating the configuration
program (chapter 4.4.2.2.1).
3. Reboot the device via Web Interface (chapter 5.4.5.6).
Note:
It takes about 60 seconds after a reboot, that the device is completely
accessible again via serial interface, via Web Interface, and via SNMP.
If power supplies were turned off via software control before the reboot,
they will be turned on after the reboot!
If
–for any reason– neither a power cycle nor a reboot of the device
restores all functionality, a reset to factory defaults is to be considered.
The factory default settings can be restored via Web Interface (chapter
5.4.5.5).