Customer Documentation DEV 5071
26
Copyright DEV Systemtechnik GmbH 2007-2017
A timeout feature (60 seconds) is implemented within the Web Interface,
i.e. a session is automatically terminated (and the allocated license is
released) if a user who is currently logged in closes the web browser.
It is possible to start a Web Interface session on another computer using
the same user account; naturally, this automatically terminates the
session on the preceding computer.
5.4.3
Status Tab
The upper part of the Status Tab shows a simplified representation of the
front side and of the rear side of the device. Thus, a quick overview is
provided regarding the detected module configuration, and regarding the
health status of the device. The round indicators are equivalent to the
physical LEDs (green = ok, red = error, amber = service / excess tempera-
ture, or gray = off; blinking LEDs on the power supply modules will be shown
here as static, only) at the device, please refer to chapter 3.2.1 for details on
the indicator information.
The internal status table in the middle of the Status Tab additionally shows
for each power supply module the status of the AC supply, of the
temperature, and of the fan status, plus the setup and the measurement
results of the output voltage and the output current for each module. The
background of some of these fields is green, if the values are detected as ok
and it will be red, otherwise.
The centered table below shows the setup and the measurement results of
the output voltage and the output current of the DC output of the device.