Summary of Contents for DEV 2161

Page 1: ...162 1 8 DEV 2165 1 16 CFP Active L Band Splitters DEV Systemtechnik GmbH Grüner Weg 4A 61169 Friedberg GERMANY Tel 49 6031 6975 100 Fax 49 6031 6975 114 support dev systemtechnik com www dev systemtechnik com Revision 2017 12 13 DEV 91 0094 G ...

Page 2: ... 3 2 3 DEV 2165 with Option 32 6 4 INSTALLATION INSTRUCTIONS 7 4 1 Scope of Delivery 7 4 2 Installation of the Product 7 4 2 1 Mechanical Integration of the Product in a 19 Rack 7 4 2 2 Grounding and Power Connection 7 4 2 3 Connection of RF Signal Cables 8 4 3 Maintenance of the Product 8 5 OPERATION OF THE PRODUCT 9 5 1 Operation via the Device Panel 9 6 CONNECTORS 9 7 TECHNICAL DATA AND OPTIONS...

Page 3: ...assis and are equipped with one to four splitter units The DEV 216x are members of the DEV Core Function Products CFP line Compared with DEV standard products the Core Function Products provide the same superior RF transmission quality without certain features such as integrated redundant power supplies monitoring ports RF sensing and other alarm functionality DEV Systemtechnik GmbH declares that ...

Page 4: ... 16 output ports DEV 2165 Optionally the DEV 2165 can be ordered with one additional splitter unit and the DEV 2161 and the DEV 2162 can be ordered with up to three additional splitter units The splitter units provide a switchable LNB power or bias supply i e the DC supply of LNBs or of inline amplifiers can be realized through the RF input port of the splitter unit 3 1 FEATURES AND OPTIONS 3 1 1 ...

Page 5: ...e delivered with one to three additional splitter units By ordering Option 32 for the DEV 2165 the product is delivered with a second splitter unit 3 2 PRODUCT DRAWINGS The layout of the different products is almost identical In the following the DEV 2161 the DEV 2162 and the DEV 2165 are shown in their maximum configuration i e with four or two splitter units installed The appearance of smaller c...

Page 6: ...nit 1 always equipped 4 Splitter unit 4 equipped only with 3 Option 31 2 Splitter unit 2 equipped only with 1 or more Option 31 3 2 3 DEV 2165 with Option 32 Front View 1 16 Active L Band Splitter DEV 2165 Rear View Bias Bias Bias Bias Pwr Pwr Pwr Pwr 1 C 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 3 C 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 2 C 2 1 2 2 2 3 2 4 2 5 2 6 2 7 2 8 4 C 4 1 4 2 4 3 4 4 4 5 4 6 4 7 4 8 G C ...

Page 7: ...grounding bolt G is located on the left at the rear side of the product G C L E P Ethernet 18 V DC 50 VA To connect the grounding cable please take off the upper nut and the first washer of the grounding bolt G Then connect the grounding cable which must have a ring tongue terminal matching for the M4 fastening bolt The washer and the nut have to be tightened again The external power supply delive...

Page 8: ...put cables to the signal receivers to the output ports When connecting RF cables to the chassis each connector is to be tightened with a torque wrench The torque applied to 75 Ohm F connectors should not exceed 4 5 Nm 39 8 lbf in Note For the products of this series female precision F connectors are applied Make sure that the applied connectors are male precision F connectors with thin inner condu...

Page 9: ...1 1 as well 6 CONNECTORS AC Power Plug at the external power supply Connector IEC rubber connector male IEC 60320 C14 Connector screws none AC Power Plug Pin Functionality Pin 1 L Live Phase Pin 2 PE Protective Earth Pin 3 N Neutral DC Connector Plug at the chassis Connector DC coaxial connector plug for connector with OD Outer Diameter 5 5 mm 0 22 ID Inner Diameter 2 1 mm 0 08 Connector screws no...

Page 10: ...version EN 50083 2 2012 A1 2015 DIN EN 55022 2011 12 Information technology equipment Radio disturbance characteristics Limits and methods of measurement CISPR 22 2008 modified German version EN 55022 2010 DIN EN 55024 2016 05 Information technology equipment Immunity characteristics Limits and methods of measurement CISPR 24 2010 Cor 2011 A1 2015 German version EN 55024 2010 A1 2015 DIN EN 61000 ...

Page 11: ...töreigenschaften Grenzwerte und Messverfahren CISPR 22 2008 modifiziert Deutsche Fassung EN 55022 2010 DIN EN 55024 2016 05 Einrichtungen der Informationstechnik Störfestigkeitseigenschaften Grenzwerte und Prüfverfahren CISPR 24 2010 Cor 2011 A1 2015 Deutsche Fassung EN 55024 2010 A1 2015 DIN EN 61000 3 2 2015 03 Elektromagnetische Verträglichkeit EMV Teil 3 2 Grenzwerte Grenzwerte für Oberschwing...

Page 12: ...Customer Documentation DEV 2161 DEV 2162 DEV 2165 12 Copyright DEV Systemtechnik GmbH 2011 2017 9 2 CERTIFICATE OF CONFORMANCE EXTERNAL POWER SUPPLY ...

Page 13: ...FP 1 8 Active Splitter 500 2300 MHz 75 Ohm F f DEV 2165 CFP 1 16 Active Splitter 500 2300 MHz 75 Ohm F f Options 30 for DEV 2161 31 for DEV 2162 32 for DEV 2165 and future options to which this declaration refers to is in conformity with Directive 2011 65 EU of the European Parliament and of the Council of 8 Jun 2011 on the restriction of the use of certain hazardous substances in electrical and e...

Page 14: ... Function Products product line within the DEV Systemtechnik product portfolio DC Direct Current IRD Integrated Receiver Decoder also simply referred to as receiver LED Light Emitting Diode LNB Low Noise Block Converter RF Radio Frequency RU Rack Unit Units of vertical height 1 RU 1 44 45 mm Sometimes simply referred to as U Unit 11 NOTES ...