65 Aleksandar Stamboliyski Str., 8000 Bourgas, Bulgaria
Tel: +359 56 820027, Fax: +359 56 836700
E-mail: office@devabroadcast.com ,Web: www.devabroadcast.com
- 53 -
CHANNELS SETTINGS (CHANNELS 1 TO 6)
The DB4402-V2 can monitor up to 6 FM Stations at regular intervals and send warning and
alarm notifications via E-mail, SMS, SNMP and GPO. Every Channel consists of a group of
settings (explained in details below), which are used when monitoring and alerting. Each preset
has its own page where it is being configured. Measurement windows can be set for each of the
six parameters: RF, Left and Right audio levels, MPX (baseband) deviation, Pilot and RDS/RBDS
deviation. Trigger and alarm release times can be set for each alarm.
The notification means (Email, SMS, SNMP, GPO) is set for each parameter individually. To
enable the notification, press on the relevant button so that it could be illuminated in green.
Channel
•
[Enabled] / [Disabled] channel monitoring and sending of warnings and alarms. If the
channel is not generally enabled, the frequency will not be monitored and alarm notifications
will not be received;
•
Frequency – specify the frequency to be monitored;
•
Name – channel alias. The same name will appear on the quick access buttons in the
“dashboard”;
•
Acquisition time – specify the observation time for the current station (before switching to
the next channel).
NOTE:
In order for the applied settings to be used press the [Save] button, placed on the
bottom right part of the screen.