Representative Digital I/O
Schematic
Analogue inputs
Four independent analogue input channels are provided for sampling voltages up to 3.3V. Each
channel is also filtered with a 10k resistor and a 100n capacitor to stabilise high frequency
jitter, there is also a pull down resistor so the port will read around 0 when nothing is
connected. 5V inputs can be used, although the 3.3V to 5V region will merely read full scale.
Examples
Example input - connecting a
potentiometer
Connecting a potentiometer should be the
simplest of tasks, either end of the pot should
be wired to the 5v and 0v respectively, the
output pin of the pot is then wired into the
analogue (A) pin. Please note the reading
from the conversion will reach maximum at
3.3V.