R
%
5(
H
Changing parameters menu
Roll up or down the menu in pushing on
keys, press the select button
to change menu
Menu : CHANGING DATA
SYSTEM
With the steam bath switched on, press the
key until the Changing system parameters menu
is displayed. Press the key and the first
digit will flash. Using the and keys,
enter the first digit of the access code and press
to confirm. The next digit will start to flash.
Repeat for a second and third digit of the access
code.
ENTER ACCESS CODE :
XXX
For gaining entry, please enter
your access code here
Access code = 234
STEAM BATH CONTROL
Allows the selection of the steam control
If steam bath EG
SELECTION :
LIMITATION :
STEAM FLOW
( ° C)
(between steam bath or on/off)
Permits to restrict the steam flow from
20 % to 100% in ON/OFF and other controls.
If steam bath HG
the display reads
Permits
to set the
perfume
injecting
frequency
in minutes
PERFUME INJECTION
FREQUENCY
MN
Permits to set
the perfume
injecting time
in seconds
T°C STEAM BATH
ADJUSTMENT
PERFUME INJECTING
TIME SEC
Permits to set
the steam
bath
temperature
Permits to set
PERFUME INJECTING
the perfume
injecting
FREQUENCY MIN
frequency in
minutes
CLEANING FREQUENCY
KG/V
Allows to set an estimed number of kg
of produced steam before a maintenance
cylinder warning message is displayed
Allows to set an estimed number of running
hours before a maintenance cylinder warning
message is displayed
CLEANING FREQUENCY
FOAM/SCALE CONTROL
SEC
31
Enables the setting of the time of the short
draining whenever the cylinder is filled in