ElectroVap®
ELMC-SB
41
6
MAINTENANCE
6.1
GENERAL INFORMATION
Periodic checks
•
After an hour of operation, check for no water leaks in the middle and foot of the cylinder.
•
After 50 hours of operation, check the condition of the cylinder. Make sure no arcing or flicker occurs between
the electrodes during operation.
Check the filter inside the water inlet valve as well as the drain system.
Please re-examine all the power cable connection terminals, as well as the clamps of the various pipes (steam,
drain, inside the wet part).
WARNING!
Tighten the clamps when the cylinder is cold.
•
After a year of operation, please check the condition of your steam hose, water drain and the internal pipes of the
unit. If some pipes seem damaged, it is essential to change them. Please tighten all connection terminals.
Warnings
After a prolonged use or with the use of high TH water, may be solid deposits on the electrodes which can increase
the concentration of water.
If electrical arcs appear inside the cylinder, your steam generator works under abnormal conditions and these arcs can
cause:
•
A significant heat increase that could overheat the plastic and even melt it, causing a hole and then a leak into the
unit.
•
A disjunction of the device due to a high intensity created by the electrical arcs.
•
Premature deterioration of heating electrodes.
•
Burning of electrodes power cables.
In case of electric arcs
Check any points in case electrical arcs appear inside the cylinder:
•
If your water is running with softened water, make sure your softener does not release salt into the appliance's
water supply pipes.
•
Make sure the drain valve is working properly and maintain it.
•
Check F3 drain valve fuse on the main board.
The steam generator has powered electrical components and the cylinder has heated elements.
Therefore, all work must be carried out by qualified and competent personnel.
Before working on the cylinder, make sure that the steam generator is switched off.
Summary of Contents for ElectroVap ELMC 20-30 SB
Page 1: ...STEAM GENERATOR FOR STEAM ROOM ElectroVap ELMC SB Series Instruction Operation Manual ...
Page 25: ...ElectroVap ELMC SB 25 3 8 6 Wiring diagrams ELMC 5 to 10 Up V 1x200 240V 50 60Hz ...
Page 26: ...ElectroVap ELMC SB 26 ELMC 5 to 30 Up V 3x200 690V 50 60Hz ...
Page 27: ...ElectroVap ELMC SB 27 ELMC 40 to 60 Up V 3x200 690V 50 60Hz ...
Page 28: ...ElectroVap ELMC SB 28 ELMC 90 Up V 3x200 690V 50 60Hz ...
Page 29: ...ElectroVap ELMC SB 29 3 9 OPTION Transformer connection ...
Page 51: ...ElectroVap ELMC SB 51 ...