ElectroVap®
ELMC-SB
13
3.4
STEAM OUTLET
1.
Preferably use a flexible steam hose that can withstand a temperature of 100°C.
Note: When new hoses are installed, a burnt plastic odor may occur when the steam generator is first turned on.
This smell is normal and will decrease in time.
2.
Selection of the steam hose:
Model
ELMC
5 à 15 SB
ELMC
20 à 30 SB
ELMC
40 à 60 SB
ELMC
90 SB
Quantity of steam outlets
1
1
2
3
Steam outlet diameter [mm]
Ø 40-25
Ø 40-25
Ø 40-25
Ø 40-25
3.
Pour For the installation of the steam hose, according to your environment, please respect the recommendations
below and use the appropriate tangential clamps.
•
Flexible steam hose max. length 3 m.
•
Rigid stainless steel or copper tube with a slightly larger diameter, connected to earth. A flexible steam hose
sleeve should be used to connect the generator to the rigid steam pipe. The length of the pipe should not
exceed 6 m and it should be insulated.
Steam Bath
Right
installation
Fig. A 3-4. Standard
Installation
500 mm mini
6 m maxi
R
Steam hose
Check that the steam
hose is not punctured and/or
that it does not form a water
pocket.
Failure to do so may
result in serious malfunctions.
Wrong
installation
R : Bending radius of
the steam hose
Ø 25 - 250mm min
Ø 40 - 400mm min
Technical
room
R
Summary of Contents for ElectroVap ELMC 20-30 SB
Page 1: ...STEAM GENERATOR FOR STEAM ROOM ElectroVap ELMC SB Series Instruction Operation Manual ...
Page 25: ...ElectroVap ELMC SB 25 3 8 6 Wiring diagrams ELMC 5 to 10 Up V 1x200 240V 50 60Hz ...
Page 26: ...ElectroVap ELMC SB 26 ELMC 5 to 30 Up V 3x200 690V 50 60Hz ...
Page 27: ...ElectroVap ELMC SB 27 ELMC 40 to 60 Up V 3x200 690V 50 60Hz ...
Page 28: ...ElectroVap ELMC SB 28 ELMC 90 Up V 3x200 690V 50 60Hz ...
Page 29: ...ElectroVap ELMC SB 29 3 9 OPTION Transformer connection ...
Page 51: ...ElectroVap ELMC SB 51 ...