ELECTROVAP
®
RTH-HC
53
5.6
DEFAULT MESSAGE
Meaning:
The temperature inside the tank is too high: 110 °C. The heating
elements are no longer completely immersed.
In this case:
When this message appears, the tank is drained, the general
fault contact is activated, and the unit is then stopped.
Possible causes and resolutions:
1.
Poor water supply from the tank.
A block of limestone obstructs the tank water inlet. The tank must be
cleaned.
2.
Level sensor issue.
Check the correct electrical connection between the level sensor and the main board
(see wiring diagrams, pg. 29). Floats visual checking and cleaning if needed.
3.
Defective temperature sensor or calibration to be redone.
If this message appears when the tank is cold, the
temperature sensor (PT100) must be tested and replaced if necessary. Then contact your agent to recalibrate.
4.
Water quality issue.
Foam occurs in the tank; the purging time must be increased. From the "CHANGE
PARAMETERS" menu find the "DRAIN TYPE" menu and activate the mode: " TIMED". Also check the
regeneration times of the softener if it is supplied with softened water.
5.
Electronic issue.
Replace the main board and check that there is no steam or water flow in the electrical
compartment.
A1: TANK TEMP.
OVER-HEAT
Summary of Contents for ElectroVap RTH-HC Series
Page 1: ...ElectroVap HUMIDIFIERS RTH HC Series Instruction Operation Manual ...
Page 30: ...ELECTROVAP RTH HC 30 3 8 6 Wiring diagrams Up V 1x200 240V 50 60Hz ...
Page 31: ...ELECTROVAP RTH HC 31 RTH HC 8 18 Up V 3x200 240V 50 60Hz ...
Page 32: ...ELECTROVAP RTH HC 32 RTH HC 5 30 Up V 3x380 690V 50 60Hz ...
Page 33: ...ELECTROVAP RTH HC 33 RTH HC 40 50 Up V 3x380 690V 50 60Hz ...
Page 34: ...ELECTROVAP RTH HC 34 RTH HC 60 70 Up V 3x380 690V 50 60Hz ...
Page 35: ...ELECTROVAP RTH HC 35 RTH HC 80 100 Up V 3x380 690V 50 60Hz ...
Page 36: ...ELECTROVAP RTH HC 36 RTH HC 8 18 Up V 3x200 240V 50 60Hz ...
Page 37: ...ELECTROVAP RTH HC 37 RTH HC 44 Up V 3x200 240V 50 60Hz ...
Page 39: ...ELECTROVAP RTH HC 39 Case 2 Up V 3x200 240V 50 60Hz Only for Case 3 ...
Page 40: ...ELECTROVAP RTH HC 40 Case 3 Up V 3x380 690V 50 60Hz ...
Page 42: ...ELECTROVAP RTH HC 42 3 9 OPTION TRANSFORMER CONNECTION ...