3 - Installation
3.1 PROCEDURE
•
Using the drilling template that came with the device, mark and drill where indicated (holes depending
on the selected dowels and support materials).
•
Put the dowels in the holes.
•
Screw the top screws into the dowels, let them protrude by about 10 mm.
•
Hang the device on the
upper
screws, screw without blocking.
•
Untighten slightly the screwing knob (Fig. 1_point 1)
•
Tilt the stainless steel tank up to tighten the tank holding chain (Fig. 1_points 2 & 3)
•
Take the water sensor wires off the water level detector (Fig. 1_point 4)
•
Untighten the clamp holding the water level pressure hose and remove the latter from the cover of the
tank
(Fig. 2_dotted zone)
Fig. 1
5
3
1
2
All in all, you must have 7 fixing points : 3 upwards and 4 downwards
(See next page for
detailed view)
.
Fig. 2