IMPORTANT

:  

To  avoid  risk  of  injury,  DEVDEEP  SOLAR  strongly  recommend  the  services  of  a  qualified 
professional  who  is  trained  in  occupational  health  and  safety  procedures,  to  clean  solar 
electricity panels.

 

 
Introduction

 

Congratulations  on  the  purchase  of  your  solar  electricity  system.  Not  only  are  you  protecting 

yourself  from  current  and  future  price  rises  of  electricity,  you  are  also  saving  significant  CO2 
emissions which helps reduce global warming and climate change.

 

Your system is designed to meet all Indian Standard conditions, regulations and codes. Although 

it is very low maintenance, it must always be remembered that the system generates electricity and 
we strongly recommend that you do not attempt to service it yourself unless you are suitably qualified. 

 Your safety is our primary concern

 

 

Owner Safety for Maintenance

 

For  your  safety,  we  recommend  that  you  do  not  attempt  any  servicing  yourself  unless  you  are 

suitably qualified.

 

 

The solar panels work best when clean. Regular rainfall or washing with a hose will maintain their 

cleanliness.  If they do become excessively soiled they can be cleaned  with cold water. DEVDEEP 
SOLAR strongly recommend that you avoid climbing onto the roof and use the services of a qualified 
professional who is trained in occupational health and safety procedures.

 

 

Shading of the solar panels will affect efficiency and performance. Plant and tree growth that may 

cause shading at various times of the year, should be monitored and dealt with as required. Likewise, 
leaves, bird droppings and other debris coming to rest either on or around the solar modules should 
be carefully removed.

 

 

If  you  notice  your  system  is  not  operating  correctly,  please  check  the 

TROUBLE  SHOOTING 

chapter  on  page  7  and  if  necessary  call  9726879009  immediately  and  we  will  help  you  to  diagnose 
your  problem  and  can  arrange  to  send  a  technician  to  resolve  it    if  necessary.    If  you  need  to  shut 
down the system, please follow these steps in this order–

 

 

1. 

Switch OFF the 

Solar Supply Main Switch 

in the Main Switchboard or Meter Box

 

2. 

Switch OFF the 

AC Isolator and DC Isolator 

adjacent to the Inverter

 

 

Following these steps will safely isolate the solar array. To switch it back on, you simply reverse the 

procedure. 

Always  remember  that  your  system  will  be  generating  electricity  during  daylight  hours  and  care 

should always be taken to eliminate the risk of electric shock. Refer to the 

OPERATING INSTRUCTIONS 

on page 5 for more information.

 

 

 

 

 

 

 

Summary of Contents for Solar

Page 1: ...Solar Power Owner s Manual DEVDEEP ELECTRICALS Roof Top Grid Connected Solar PV System ...

Page 2: ...uctions 5 Operating Safety Instructions 5 Trouble Shooting 6 Maintenance of Solar PV System Equipments 7 Important Reminder 8 Warranty 8 AccreditedInstallerDetails 9 Expected System Performance 9 Actual System Performance 9 Maintenance and Fault Log 10 Inverter Details 11 Array Details 11 Disclaimer 12 Table of Contents ...

Page 3: ...r DEVDEEP SOLAR strongly recommend that you avoid climbing onto the roof and use the services of a qualified professional who is trained in occupational health and safety procedures Shading of the solar panels will affect efficiency and performance Plant and tree growth that may cause shading at various times of the year should be monitored and dealt with as required Likewise leaves bird droppings...

Page 4: ...ion 3 Depending on Local Regulations Your Solar system may be connected to the grid on a Net Metering System With Net Metering only the Electricity not First consumed by the House will be Exported to the Grid If you have an Old Electro Mechanical Meter with the spinning disk this will need to be replaced with a Bi Directional Meter able to record the electricity you both import and export Your Ele...

Page 5: ...d if necessary call 9726879009 Immediately and we will diagnose your problem and send a technician to resolve it if necessary Operating Safety Instructions Do not Attempt to Service the system unless you are Fully Qualified to do so To service any Electrical connection you have MUST be a Licensed Electrician All Service work must be carried out in strict compliance with all Local and National Elec...

Page 6: ...Breaker If It Trips Again Contact us Check Grid Contactor coil Fuse Check Grid Frequency Low High Condition Check Phase Rotation Output Under Voltage i Output Short Circuit ii Inverter Control Card Failed iii Driver Card Failed iv Driver Control Failed v Filter Capacitor Failed vi No Feed Forward Signal vii Hall Device Failed viii IGBT Module Failed Check load is Proper or Not To Reset the Fault P...

Page 7: ...ture at the highest point of Tilt This minimum space is required to avoid shadow of one row of solar structure to fall on the row behind it There must not be any obstacles near to PV Module installation area So that shadow will affect the generation Do not step or walk on the Modules or else the warranty of the modules will be void During the generation hours there should not be any shadow reflect...

Page 8: ...s Manual in a Safe and Easily Locatable Place Together with all other documentation supplied with your system Warranty In the case of a service being required please make available all the documentation to the service technician Note that the manufacturers warranties may be voided if the system is serviced or interfered with by an unqualified person Your solar electric system comes with the follow...

Page 9: ...System Performance to be completed by accredited installer 1 Size of Solar Array in Kilowatts kW 2 Maximum AC output of Inverter in Kilowatts kW 3 Elevation angle Expected loss 4 Shading of solar array Expected loss 5 Expected Average Daily output of Solar Array in Kilowatt hours kWh 6 Location of Inverter 7 Location of PV array s Actual System Performance to be completed by owner Date of connecti...

Page 10: ... and Fault Log Please do not climb above 2 meters to maintain solar modules without observing all OH S regulations Use only clean water to clean solar modules no detergents or solvents Date Problem Remedy Electrician ...

Page 11: ...Model Size Array Details Module type Model SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN SN VOC ARRAY 1 VDC VOC ARRAY 2 VDC VMP ARRAY 1 VDC VMP ARRAY 2 VDC ...

Page 12: ...ectly This manual provides guidelines for Operation Maintenance DEVDEEP SOLAR is not responsible for any damages caused by using or installing our products be it Personal Injury Damage of Property Prosecution from a result of using our products legal fees or loss of earnings and whether the DEVDEEP SOLAR product was fitted correctly as per this Maintenance Guide or not DEVDEEP SOLAR www devdeepele...

Reviews: