FrameMaker Ver.5.5E(PC) Di250 DIS/REASSEMBLY, ADJUSTMENT
99.01.07
D-35
1. Leading
Requirement
NOTE
This adjustment must be made when the PH Unit has been replaced and after Registration
(CD/FD) (Printer) has been made.
Adjustment Procedure
1. Call the Tech. Rep. mode to the screen.
2. Touch [Tech. Rep. Choice], then [Printer].
3. Touch [Edge Erase] and then [Leading] to enter the Leading Edge Erase adjustment
mode.
4. Press the Clear key to clear the current setting.
5. Enter the new setting value from the 10-Key Pad.
Setting Instructions
To make the edge erase width smaller, decrease the setting value.
To make the edge erase width greater, increase the setting value.
6. Touch the [END] key to validate the setting value.
Caution
Be sure to touch the END key before returning to normal operation mode. If the Panel
Reset Key is used, the previous setting remains valid.
(4) Edge Erase
Adjust so that the erase width on the leading edge falls
within the range of 0 to 5 mm.
Adjust Mode
Setting Range
Edge Erase/Leading
0 to 5
1171D003AA
A
1171D031CA
1167D069AA
Setting Value
Use to clear setting value.
Use to enter setting value.