Scanner FD Zoom Adjustment
Requirement
• Adjust so that the amount of error falls within ±1.0 % of the length to be measured.
• Adjust so that the following specifications are met when the length of the scale is 300
mm.
NOTE
• This adjustment is made when the Scanner Drive Cables have been replaced.
<Adjustment Procedure>
1. Place a scale on the Original Glass in parallel with the Original Length Scale and make
a copy.
3. Enter the Adjust mode.
4. With “AJ-” shown on the Display, enter the code number “4” from the 10-Key Pad and
press the Start key to enter the “Scanner FD Zoom Adjustment” mode.
5. Press the Clear key to clear the current setting value.
6. Enter the new setting value from the 10-Key Pad and press the Start key to validate the
entry.
Adjustment Instructions
If the length on the copy is longer than the actual one, decrease the setting value.
If the length on the copy is shorter than the actual one, increase the setting value.
If a single adjustment procedure does not successfully bring the amount of error into the
specified range, repeat steps 3 though 6.
Zoom Ratio
Specifications
Mode
Code No.
Setting Range
Full size (
×
1.00)
300 ± 3.0 mm
Adjust
4
97 to 103,
1 step: 0.4 %
2. Measure the length of the scale on the copy.
If the amount of error falls outside the specified
range, perform the following steps to make an
adjustment.
Summary of Contents for D1531iD
Page 2: ...FrameMaker Ver5 5E PC Di152 Di183 GENERAL 01 08 27 GENERAL 14413 ...
Page 3: ......
Page 5: ......
Page 15: ......
Page 16: ...FrameMaker Ver5 5E PC Di152 Di183 MECHANICAL ELECTRICAL 01 09 05 MECHANICAL ELECTRICAL 14413 ...
Page 17: ......
Page 73: ......
Page 85: ......
Page 89: ......
Page 161: ......
Page 163: ......
Page 193: ......
Page 194: ...FrameMaker Ver 5 5E PC Di152 Di183 TROUBLESHOOTING 01 09 04 TROUBLESHOOTING 14390 ...
Page 195: ......
Page 259: ......