Field Service Ver. 1.0 Apr. 2005
15. Malfunction code
135
ineo 161
ineo 210
T
roubleshooting
15.3 Solution
15.3.1
C0000: Main Motor malfunction
A. Detection Timing
B. Action
Trouble Code
Description
C0000
• The Main Motor (M1) Lock signal remains HIGH for a continuous 1-sec. period
at any time 1 sec. after the Main Motor has started turning.
Relevant Electrical Components
Main Motor (M1)
Master Board (PWB-A)
Power Supply Unit (PU1)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check M1 connectors for proper con-
nection and correct as necessary.
–
–
–
2
Check M1 for correct drive coupling
and correct as necessary.
–
–
–
3
M1 operation check.
☞
–
I-14
4
Change PWB-A.
–
–
–
5
Change PU1.
–
–
–