Field Service Ver. 1.0 Apr. 2005
15. Malfunction code
139
ineo 161
ineo 210
T
roubleshooting
15.3.5
C0070: Toner Replenishing Motor Malfunction
A. Detection Timing
B. Action
Trouble Code
Description
C0070
• The Toner Bottle Home Position Sensor (PC7) outputs a HIGH signal for a con-
tinuous 3.5-sec. period while the Toner Bottle is turning.
• The Toner Bottle Home Position Sensor (PC7) outputs a LOW signal for a con-
tinuous 2-sec. period while the Toner Bottle is turning.
Relevant Electrical Components
Toner Replenishing Motor (M6)
Toner Bottle Home Position Sensor (PC7)
Master Board (PWB-A)
Power Supply Unit (PU1)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check M6 connectors for proper con-
nection and correct as necessary.
–
–
–
2
Check M6 for correct drive coupling
and correct as necessary.
–
–
–
3
M6 operation check
☞
PWB-A PJ16A-1 (REM)
B-8
4
PC7 sensor check
☞
PWB-A PJ16A-5 (ON)
B-8
5
Change PWB-A.
–
–
–
6
Change PU1.
–
–
–