15. Malfunction code
Field Service Ver. 1.0 Apr. 2005
144
ineo 161
ineo 210
T
roubleshooting
15.3.13
C0650: Faulty Scanner Home Position Sensor
A. Detection Timing
B. Action
Trouble Code
Description
C0650
• The Scanner Home Position Sensor (PC10) does not go from HIGH to LOW
when the Scanner Motor (M5) is energized for a given number of steps after the
sequence to bring the Scanner back to its home position has been started at
the end of a scan motion and during re-shading.
• The Scanner Home Position Sensor (PC10) does not go from LOW to HIGH
when the Scanner Motor (M5) is energized for a given number of steps after a
scan motion has been started at the end of a Scanner Home Position Sensor
home check scan motion and during re-shading.
Relevant Electrical Components
Scanner Motor (M5)
Scanner Home Position Sensor (PC10)
Control Board (PWB-C/C)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check M5 connectors for proper con-
nection and correct as necessary.
–
–
–
2
Check M5 for correct drive coupling
and correct as necessary.
–
–
–
3
M5 operation check
☞
–
B-11
4
Scanner operation check
–
–
–
5
PC10 sensor check
☞
PWB-C/C
P114C/C-3 (ON)
B-13
6
Change PWB-C/C.
–
–
–