15. Malfunction code
Field Service Ver. 1.0 Apr. 2005
150
ineo 161
ineo 210
T
roubleshooting
15.3.23
C14A3: IR Fluorescent Lamp Fault
A. Detection Timing
B. Action
Trouble Code
Description
C14A3
The Exposure Lamp (LA2) of the Scanner fails to turn ON.
• The intensity of the Exposure Lamp is a predetermined value or less during
shading and re-shading.
Relevant Electrical Components
Exposure Lamp (LA2)
Inverter Board (PU2)
CCD Board (PWB-J)
Control Board (PWB-C/C)
Step
Operations
Ref.
Page
WIRING DIAGRAM
Control signal
Location
(Electrical
Components)
1
Check that the Exposure Lamp (LA2)
turns ON when the Power Switch is
turned ON and correct or replace as
necessary.
–
–
–
2
Check connectors on PU2 for proper
connection and correct as necessary.
–
–
–
3
Check connectors on PWB-J for
proper connection and correct as
necessary.
–
–
–
4
Change PWB-C/C.
–
–
–