17. Image quality problem
Field Service Ver. 1.0 Apr. 2005
158
ineo 161
ineo 210
T
roubleshooting
17.2.4
Image Reading Section: Foggy background or rough image
A. Typical Faulty Images
B. Troubleshooting Procedure
4011T004AA
Step
Check
Result
Action
1
Original Glass is dirty.
YES
• Clean.
2
Scanner mirrors are dirty.
YES
• Clean.
3
Exposure Lamp (LA2) is dirty.
YES
• Clean.
4
CCD Unit lens and CCD surface are dirty.
<Check Procedure>
Remove lens cover to check for possible contamination.
YES
• Clean.
5
Exposure Lamp is abnormally lit (flickers or abnormally
dark) when the Start key is pressed.
NO
• Go to step 7.
6
Inverter Board (copier: PU2) connector is loose.
YES
• Reconnect.
NO
• Change Exposure
Lamp (LA2).
7
CCD Board (copier: PWB-J) connector is loose.
YES
• Reconnect.
NO
• Change Inverter Board
(PU2).
• Change Control Board
(copier: PWB-C).